Offset
Name
Type
Description
W1
RW
14.5 Register Description
14.5.1 EBI_CTRL - Control Register
Offset
Bit Position
0x000
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0x0
0x0
0x0
0x0
Access
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
Name
Bit
Name
Reset
Access
Description
31
ALTMAP
0
RW
Alternative Address Map Enable
This field enables or disables the alternative (256 MB per bank) address map.
30
ITS
0
RW
Individual Timing Set, Line Polarity and Mode Definition Enable
This field enables or disables individual timing sets, line polarities and modes per bank.
29:28
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in Section 2.1 (p. 3)
27
BL3
0
RW
Byte Lane Enable for bank 3
Enables or disables the Byte Lane functionality for bank 3. Ignored when ITS = 0.
26
BL2
0
RW
Byte Lane Enable for bank 2
Enables or disables the Byte Lane functionality for bank 2. Ignored when ITS = 0.
25
BL1
0
RW
Byte Lane Enable for bank 1
Enables or disables the Byte Lane functionality for bank 1. Ignored when ITS = 0.
24
BL
0
RW
Byte Lane Enable for bank 0
Enables or disables the Byte Lane functionality for bank 0. Applies to all banks when ITS = 0. Applies to only bank 0 when ITS = 1.
23
ARDYTO3DIS
0
RW
ARDY Timeout Disable for bank 3
Enables or disables the ARDY timeout functionality for bank 3. The timeout value is 32 internal clock cycles. Ignored when ITS = 0.
22
ARDY3EN
0
RW
ARDY Enable for bank 3
Enables or disables the ARDY functionality for bank 3. Ignored when ITS = 0.
21
ARDYTO2DIS
0
RW
ARDY Timeout Disable for bank 2
Enables or disables the ARDY timeout functionality for bank 2. The timeout value is 32 internal clock cycles. Ignored when ITS = 0.
20
ARDY2EN
0
RW
ARDY Enable for bank 2
Enables or disables the ARDY functionality for bank 2. Ignored when ITS = 0.
19
ARDYTO1DIS
0
RW
ARDY Timeout Disable for bank 1
Enables or disables the ARDY timeout functionality for bank 1. The timeout value is 32 internal clock cycles. Ignored when ITS = 0.
18
ARDY1EN
0
RW
ARDY Enable for bank 1
Enables or disables the ARDY functionality for bank 1. Ignored when ITS = 0.
17
ARDYTODIS
0
RW
ARDY Timeout Disable
Enables or disables the ARDY timeout functionality. The timeout value is 32 internal clock cycles. Applies to all banks when ITS =
0. Applies to only bank 0 when ITS = 1.
16
ARDYEN
0
RW
ARDY Enable
Enables or disables the ARDY functionality. Applies to all banks when ITS = 0. Applies to only bank 0 when ITS = 1.
Summary of Contents for EFM32G