...the world's most energy friendly microcontrollers
2014-07-02 - Gecko Family - d0001_Rev1.30
231
www.silabs.com
Bit
Name
Reset
Access
Description
Value
Description
0
Output from the transmitter is passed unchanged to U(S)n_TX
1
Output from the transmitter is inverted before it is passed to U(S)n_TX
13
RXINV
0
RW
Receiver Input Invert
Setting this bit will invert the input to the USART receiver.
Value
Description
0
Input is passed directly to the receiver
1
Input is inverted before it is passed to the receiver
12
TXBIL
0
RW
TX Buffer Interrupt Level
Determines the interrupt and status level of the transmit buffer.
Value
Mode
Description
0
EMPTY
TXBL and the TXBL interrupt flag are set when the transmit buffer becomes empty.
TXBL is cleared when the buffer becomes nonempty.
1
HALFFULL
TXBL and TXBLIF are set when the transmit buffer goes from full to half-full or empty.
TXBL is cleared when the buffer becomes full.
11
CSMA
0
RW
Action On Slave-Select In Master Mode
This register determines the action to be performed when slave-select is configured as an input and driven low while in master mode.
Value
Mode
Description
0
NOACTION
No action taken
1
GOTOSLAVEMODE
Go to slave mode
10
MSBF
0
RW
Most Significant Bit First
Decides whether data is sent with the least significant bit first, or the most significant bit first.
Value
Description
0
Data is sent with the least significant bit first
1
Data is sent with the most significant bit first
9
CLKPHA
0
RW
Clock Edge For Setup/Sample
Determines where data is set-up and sampled according to the bus clock when in synchronous mode.
Value
Mode
Description
0
SAMPLELEADING
Data is sampled on the leading edge and set-up on the trailing edge of the bus clock
in synchronous mode
1
SAMPLETRAILING
Data is set-up on the leading edge and sampled on the trailing edge of the bus clock
in synchronous mode
8
CLKPOL
0
RW
Clock Polarity
Determines the clock polarity of the bus clock used in synchronous mode.
Value
Mode
Description
0
IDLELOW
The bus clock used in synchronous mode has a low base value
1
IDLEHIGH
The bus clock used in synchronous mode has a high base value
7
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in Section 2.1 (p. 3)
6:5
OVS
0x0
RW
Oversampling
Sets the number of clock periods in a UART bit-period. More clock cycles gives better robustness, while less clock cycles gives
better performance.
Value
Mode
Description
0
X16
Regular UART mode with 16X oversampling in asynchronous mode
1
X8
Double speed with 8X oversampling in asynchronous mode
2
X6
6X oversampling in asynchronous mode
3
X4
Quadruple speed with 4X oversampling in asynchronous mode
4
MPAB
0
RW
Multi-Processor Address-Bit
Defines the value of the multi-processor address bit. An incoming frame with its 9th bit equal to the value of this bit marks the frame
as a multi-processor address frame.
3
MPM
0
RW
Multi-Processor Mode
Summary of Contents for EFM32G