Bit
Name
Reset
Access Description
31:28
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
27:24
PRSDOWNSEL
0x0
RW
PRS Select for PRS Input when selected in DOWNSEL
Select PRS input for PRS based calibration. Only change when calibration circuit is off.
Value
Mode
Description
0
PRSCH0
PRS Channel 0 selected as input
1
PRSCH1
PRS Channel 1 selected as input
2
PRSCH2
PRS Channel 2 selected as input
3
PRSCH3
PRS Channel 3 selected as input
4
PRSCH4
PRS Channel 4 selected as input
5
PRSCH5
PRS Channel 5 selected as input
6
PRSCH6
PRS Channel 6 selected as input
7
PRSCH7
PRS Channel 7 selected as input
8
PRSCH8
PRS Channel 8 selected as input
9
PRSCH9
PRS Channel 9 selected as input
10
PRSCH10
PRS Channel 10 selected as input
11
PRSCH11
PRS Channel 11 selected as input
23:20
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
19:16
PRSUPSEL
0x0
RW
PRS Select for PRS Input when selected in UPSEL
Select PRS input for PRS based calibration. Only change when calibration circuit is off.
Value
Mode
Description
0
PRSCH0
PRS Channel 0 selected as input
1
PRSCH1
PRS Channel 1 selected as input
2
PRSCH2
PRS Channel 2 selected as input
3
PRSCH3
PRS Channel 3 selected as input
4
PRSCH4
PRS Channel 4 selected as input
5
PRSCH5
PRS Channel 5 selected as input
6
PRSCH6
PRS Channel 6 selected as input
7
PRSCH7
PRS Channel 7 selected as input
8
PRSCH8
PRS Channel 8 selected as input
9
PRSCH9
PRS Channel 9 selected as input
10
PRSCH10
PRS Channel 10 selected as input
11
PRSCH11
PRS Channel 11 selected as input
15:9
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
8
CONT
0
RW
Continuous Calibration
EFM32JG1 Reference Manual
CMU - Clock Management Unit
silabs.com
| Smart. Connected. Energy-friendly.
Preliminary Rev. 0.6 | 251