...the world's most energy friendly microcontrollers
2014-07-02 - Tiny Gecko Family - d0034_Rev1.20
413
www.silabs.com
Bit
Name
Reset
Access
Description
2
ADJ
0
RW
Single Sample Result Adjustment
Select single sample result adjustment.
Value
Mode
Description
0
RIGHT
Results are right adjusted
1
LEFT
Results are left adjusted
1
DIFF
0
RW
Single Sample Differential Mode
Select single ended or differential input.
Value
Description
0
Single ended input
1
Differential input
0
REP
0
RW
Single Sample Repetitive Mode
Enable/disable repetitive single samples.
Value
Description
0
Single conversion mode is deactivated after one conversion
1
Single conversion mode is converting continuously until SINGLESTOP is written
24.5.5 ADCn_SCANCTRL - Scan Control Register
Offset
Bit Position
0x010
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reset
0x0
0
0x0
0x0
0x00
0x0
0
0
0
Access
RW
RW
RW
RW
RW
RW
RW
RW
RW
Name
Bit
Name
Reset
Access
Description
31
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in Section 2.1 (p. 3)
30:28
PRSSEL
0x0
RW
Scan Sequence PRS Trigger Select
Select PRS trigger for scan sequence.
Value
Mode
Description
0
PRSCH0
PRS ch 0 triggers scan sequence
1
PRSCH1
PRS ch 1 triggers scan sequence
2
PRSCH2
PRS ch 2 triggers scan sequence
3
PRSCH3
PRS ch 3 triggers scan sequence
4
PRSCH4
PRS ch 4 triggers scan sequence
5
PRSCH5
PRS ch 5 triggers scan sequence
6
PRSCH6
PRS ch 6 triggers scan sequence
7
PRSCH7
PRS ch 7 triggers scan sequence
27:25
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in Section 2.1 (p. 3)
24
PRSEN
0
RW
Scan Sequence PRS Trigger Enable
Enabled/disable PRS trigger of scan sequence.
Value
Description
0
Scan sequence is not triggered by PRS input
1
Scan sequence is triggered by PRS input selected by PRSSEL
23:20
AT
0x0
RW
Scan Sample Acquisition Time
Select the acquisition time for scan samples.