GND
CMPnP.0
CMPnP.1
CMPnP.2
CMPnP.3
CMPnP.x
CMXP
CMPn+
CMPn-
Figure 13.4. Negative Input Ground Connection
When INSL is configured to use the reference DAC on the negative channel, the positive comparator mux selection is directly connec-
ted to the positive comparator input. The negative mux selection becomes the full scale voltage reference for the DAC, and the DAC
output is connected to the negative comparator input.
CMPnP.0
CMPnP.1
CMPnP.2
CMPnP.3
CMPnP.x
CMPnN.0
CMPnN.1
CMPnN.2
CMPnN.3
CMPnN.x
CMPn+
CMPn-
DACLVL
CMXP
CMXN
DAC
Full Scale Reference
Figure 13.5. Negative Input DAC Connection
When INSL is configured to use the reference DAC on the positive channel, the negative comparator mux selection is directly connec-
ted to the negative comparator input. The positive mux selection becomes the full scale voltage reference for the DAC, and the DAC
output is connected to the positive comparator input.
EFM8UB3 Reference Manual
Comparators (CMP0 and CMP1)
silabs.com
| Building a more connected world.
Rev. 0.2 | 152