7.9 Power Management Control Registers
7.9.1 PCON0: Power Control
Bit
7
6
5
4
3
2
1
0
Name
GF5
GF4
GF3
GF2
GF1
GF0
STOP
IDLE
Access
RW
RW
RW
RW
RW
RW
RW
RW
Reset
0
0
0
0
0
0
0
0
SFR Page = ALL; SFR Address: 0x87
Bit
Name
Reset
Access Description
7
GF5
0
RW
General Purpose Flag 5.
This flag is a general purpose flag for use under firmware control.
6
GF4
0
RW
General Purpose Flag 4.
This flag is a general purpose flag for use under firmware control.
5
GF3
0
RW
General Purpose Flag 3.
This flag is a general purpose flag for use under firmware control.
4
GF2
0
RW
General Purpose Flag 2.
This flag is a general purpose flag for use under firmware control.
3
GF1
0
RW
General Purpose Flag 1.
This flag is a general purpose flag for use under firmware control.
2
GF0
0
RW
General Purpose Flag 0.
This flag is a general purpose flag for use under firmware control.
1
STOP
0
RW
Stop Mode Select.
Setting this bit will place the CIP-51 in Stop mode. This bit will always be read as 0.
0
IDLE
0
RW
Idle Mode Select.
Setting this bit will place the CIP-51 in Idle mode. This bit will always be read as 0.
EFM8UB3 Reference Manual
Power Management and Internal Regulators
silabs.com
| Building a more connected world.
Rev. 0.2 | 66