2. Specifications
2.1 Recommended Operating Conditions
The following table is intended to serve as guideline for a correct use of EFR32FG23 Dev Kit, indicating typical operating conditions and
some design limits.
Table 2.1. Recommended Operating Conditions
Parameter
Symbol
Min
Typ
Max
Unit
USB Supply Input Voltage
V
USB
—
5.0
—
V
Battery Supply Input Voltage
V
VBAT
2.0
3.0
3.3
V
Supply Input Voltage (VMCU supplied externally)
1,2
V
VMCU
1.8
3.3
3.6
V
Operating Temperature
T
OP
—
20
—
˚C
Note:
1. The supply voltage limit may be tighter under certain conditions when using the EFR32FG23's internal dc-dc converter. For more
information see the EFR32FG23 data sheet.
2. Not recommended for use with rechargeable Lithium batteries. Most Li-Ion and Li-Po cells exceed 3.6 V when fully charged.
UG508: EFR32FG23 Dev Kit User's Guide
Specifications
silabs.com
| Building a more connected world.
Rev. 1.1 | 6