Si2401
4
Preliminary Rev. 0.9
Electrical Specifications
Table 1. Recommended Operating Conditions
Parameter
1
Symbol
Test Condition
Min
2
Typ
Max
2
Unit
Ambient Temperature
T
A
F-Grade
0
25
70
°C
Si2401 Supply Voltage, Digital
3
V
D
3.0
3.3
3.6
V
Notes:
1.
The Si2401 specifications are guaranteed when the typical application circuit (including component tolerance) and Si2401
and Si3010 are used. See "Typical Application Schematic" on page 10.
2.
All minimum and maximum specifications are guaranteed and apply across the recommended operating conditions. Typical
values apply at nominal supply voltages and an operating temperature of 25 °C unless otherwise stated.
3.
The digital supply, V
D
, operates from 3.0 to 3.6 V. The Si2401 interface supports 5 V logic (CLKIN/XTALI supports 3.3 V
logic only).