Si2401
40
Preliminary Rev. 0.9
Reset settings = 0000_0110 (0x06)
S07 (MF1). Modem Functions 1
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Name
BD
V23R
V23T
BAUD CCITT
FSK
Type
R/W
R/W
R/W
R/W
R/W
R/W
Bit
Name
Function
7
Reserved
Read returns zero.
6
BD
Blind Dialing.
0
=
Disable.
1 = Enable (Blind dialing occurs immediately after “ATDT#” command).
5
V23R
V.23 Receive.*
V.23 75 bps send/600 (BAUD = 0) or 1200 (BAUD = 1) bps receive.
0
=
Disable.
1 = Enable.
4
V23T
V.23 Transmit.*
V.23 600 (BAUD = 0) or 1200 (BAUD = 1) bps send/75 bps receive.
0
=
Disable.
1 = Enable.
3
Reserved
Read returns zero.
2
BAUD
2400/1200 Baud Select.*
2400/1200 baud select (V23R = 0 and V23T = 0).
0 = 1200
1
=
2400
600/1200 baud select (V23R = 1 and V23T = 1).
0 = 600
1
=
1200
1
CCITT
CCITT/Bell Mode.*
0 = Bell.
1
=
CCITT.
0
FSK
300 bps FSK.*
0
=
Disable.
1 = Enable.
*Note:
See Table 9 on page 13 for proper setting of modem protocols.