ZigBee Communications Gateway
©2016 Silicon Labs
-24-
ZigBee Communications Gateway
5.3.2.2 ZigBee Interface Configurations
Figure 13: ZigBee Interface Configurations page
The Gateway comes with Telegesis ZigBee AT-commands
7
Firmware programmed onto the
assembled ETRX3 ZigBee module. This firmware communicates at baud rate settings of 19200-
8N1. The ZigBee Interface Configurations page is useful to change
8
the serial settings of the gateway
serial ports connected to the ETRX3 ZigBee modules. This page also provides the options to reset
the selected ETRX3 ZigBee module and to start the bootloader.
a. Select Module
This field selects the ETRX3 ZigBee module to apply the settings to (there can be two module
as per the model number of gateway).
b. Module Control
Reset Module
Click
for gateway reset the selected ETRX3 module.
Start Bootloader
Click
to start the bootloader on selected ZigBee module. The standard AT-
Command firmware has serial Bootloader which can be used to upgrade the ZigBee firmware
in the selected module. Process of upgrading ETRX3 ZigBee firmware in standard Gateway
is described in the
Appendix A
. The bootloader is initiated by holding down the PA5 pin of
the EM35x and then issuing a hardware reset to the module
c. Serial Settings
Select the serial settings for the selected module and click
to apply the settings
7
Please refer AT-commands documentation at
Telegesis document centre
8
The Serial Port settings only apply to the Gateway. For correct operation, the Serial Port settings of the
ETRX3 module must be changed to match the new Gateway setting before changing the Gateway parameters