4.2 General Operating Conditions
This table specifies the general operating temperature range and supply voltage range for all supplies. The minimum and maximum
values of all other tables are specifed over this operating range, unless otherwise noted.
Table 4.2. General Operating Conditions
Parameter
Symbol
Test Condition
Min
Typ
Max
Unit
Operating ambient tempera-
ture range
T
A
-G temperature grade
-40
—
+85
°C
-N temperature grade
-40
—
+105
°C
IOVDDx operating supply
voltage (All IOVDD pins)
V
IOVDDx
1.71
3.0
3.8
V
VREGVDD operating supply
voltage
V
VREGVDD
2.2
3.0
3.8
V
DCDC in bypass
1.8
3.0
3.8
V
HCLK and SYSCLK frequen-
cy
f
HCLK
VSCALE2, MODE = WS1
—
—
76.8
MHz
VSCALE2, MODE = WS0
—
—
40
MHz
PCLK frequency
f
PCLK
VSCALE2
—
—
50
MHz
VSCALE1
—
—
40
MHz
EM01 Group A clock fre-
quency
f
EM01GRPACLK
VSCALE2
—
—
76.8
MHz
VSCALE1
—
—
40
MHz
EM01 Group B clock fre-
quency
f
EM01GRPBCLK
VSCALE2
—
—
76.8
MHz
VSCALE1
—
—
40
MHz
Radio HCLK frequency
f
RHCLK
VSCALE2 or VSCALE1
—
38.4
—
MHz
Note:
1. The supported maximum V
VREGVDD
in regulation mode is a function of temperature and 10-year lifetime average load current.
See more details in
.
2. The recommended radio crystal frequency is 38.4 MHz. Any crystal frequency other than 38.4 is expressly not supported.
BGM220S Wireless Gecko Bluetooth
®
Module Data Sheet
Electrical Characteristics
silabs.com
| Building a more connected world.
Rev. 1.1 | 9