5.2
Door Lock
The Z-Wave certified Door Lock application shows a lock implementation. It will support user codes to
open a door and thereby eliminate the need for traditional keys. It is possible to both lock and unlock
the door remotely through the Z-Wave protocol.
The Door Lock application is based on:
Role Type:
Listening Sleeping Slave (LSS / FLiRS)
Supporting Device Type:
Actuator
Device Type:
Lock
Generic Type:
Entry Control
Specific Type:
Door Lock
Requested security keys:
S0 and S2_ACCESS
The Door Lock features depends on the security level.
The full set of features only work when securely added to a network by a controller supporting security.
Graphical representation (Icon Types):
Not
implemented Door lock functionality:
o
Timed Operation mode
o
Door Lock condition
o
Inside Door Handle State
o
Functionality handling Lock timeout
o
Target mode
o
Auto-Relock, Hold And Release, Block to Block, and Twist Assist