INS14278-4
How to Use Certified Apps in Z-Wave 700
2019-03-22
| Building a more connected world.
Page 33 of 45
5.4.1 Supported Command Classes
Sensor PIR implements mandatory and some optional command classes. The table below lists the
supported Command Classes, their version, and their required Security class if any.
Table 17. Sensor PIR Supported Command Classes
Command Class
Version
Required Security Class
Association
2
Highest granted Security Class
Association Group Info
3
Highest granted Security Class
Battery
1
Highest granted Security Class
Device Reset Locally
1
Highest granted Security Class
Firmware Update Meta Data
5
Highest granted Security Class
Indicator
3
Highest granted Security Class
Manufacture Specific
2
Highest Granted Security Class
Multi Channel Association
3
Highest granted Security Class
Notification
8
Highest granted Security Class
Powerlevel
1
Highest granted Security Class
Security 2
1
None
Supervision
1
None
Transport Service
2
None
Version
3
Highest granted Security Class
Wake Up
2
Highest granted Security Class
Z-Wave Plus Info
2
None
5.4.2 Basic Command Class Mapping
Basic Command Class is not mapped to any of the supported command classes.