Siliken recommends that the modules not be installed at reduced inclination
angles that could cause dirt to accumulate on the glass or on the edges
of the frame. Siliken recommends a minimum inclination of 5º.
In the case of roof-top PV modules, leave space at their back side to
allow for proper ventilation (minimum of 50 mm [1.97 inches]).
For integrated modules that serve as a roof tile, it must be assured that
the rear part of the modules is ventilated.
A photovoltaic module is not a structural element. Be sure that the
module is not going to support any load that could cause the tempered
glass to break.
Maximum permitted loads for PV modules refer to uniformly distributed
loads of wind and/or snow. Therefore, do not install PV modules in areas
Mechanical assembly of the modules
24
Instructions for using photovoltaic modules
VENTILATION
50 (1.97")