Filling: 

IMPORTANT: Always make sure the pressure is released from the tank before  filling or 
servicing. 

1. Pull up on the knob of the pressure release valve until all the pressure is released from 

the tank. (

See Figure E

). 

2. Turn the pump handle counterclockwise to remove the pump (

See Figure F

). 

3. Fill the tank to the desired level. See fill markings on side of tank. (Always refer to chemical 

manufacturer for proper mixture). 

4. Install the pump into the tank opening and turn clockwise until tightly sealed against the 

tank (

See Figure G

). 

 

                  Figure E                                           Figure F                                     Figure G 

Pressurising: 

1. Make sure spray gun shut-off lock is not on. (If shut-off lock is on while pressurising, the 

unit will immediately start spraying). 

2. Push down on the handle and turn counter clockwise to unlock the handle (

See Figure-

1H

). 

3. Pressurise the sprayer by pumping the handle in a smooth up and down motion (

See 

Figure-2H

). 

4.  Push  down  on  the  handle  and  turn  clockwise  to  lock  the  handle  into  the  pump  (

See 

Figure-3H

). 

 

 

                 Figure 1H                                            Figure 2H                                          Figure 3H 

Operation 

Summary of Contents for 190545

Page 1: ...Instruction Manual MAN190545 REV A 23 04 18 PRO GRADE HAND SPRAYER 5L 8L 190545 190546 190548 190549...

Page 2: ...Do not store chemicals in this tank Always release pressure when sprayer is not in use and before performing any maintenance Clean and rinse sprayer thoroughly after each use and before and maintenanc...

Page 3: ...ozzle C Adjustable Cone Nozzle D Red High Volume Fan Nozzle E Yellow Low Volume Fan Nozzle F Flat Seal G Adapter H Extension ADJUSTABLE CONE USES FOAMING NOZZLE USES Spot spraying in or around flower...

Page 4: ...oper mixture 4 Install the pump into the tank opening and turn clockwise until tightly sealed against the tank See Figure G Figure E Figure F Figure G Pressurising 1 Make sure spray gun shut off lock...

Page 5: ...pump and tighten securely 3 Agitate the tank to rinse the chemical from the tank wall and pump 4 Remove the pump and empty the contents into gravel or bare soil 5 Refill the tank with clean tap water...

Page 6: ...e 2 3 Inspect O ring If worn or damaged remove and replace Lubricate O ring with petroleum jelly See Figure 3 4 Inspect check valve in bottom of barrel If worn or damaged remove and replace by pressin...

Page 7: ...he handle from the shut off assembly 2 Remove the filter from the shut off assembly 3 Clean any debris from inside the handle shut off assembly or the filter by rinsing with cool clean water 4 Reassem...

Page 8: ...pped torn swollen damaged pump or missing valve at bottom of pump Fig 4 1 Remove and clean dirt or debris from valve Fig 4 and sealing surface on pump 2 Replace if worn or missing valve as described i...

Page 9: ...Assembly 2 183870 Pressure Relief Valve 3 183862 Nozzle Kit 4 183871 Hand Pump Repair Kit 5 183859 Trigger Assembly Shut Off Assembly 5A 183863 Trigger Assembly Wand Repair Kit 6 183860 Stainless Stee...