background image

 
 
 
 

About your Warranty 

 

Page 3 

 

Silvan Australia Pty. Ltd. builds equipment to a high level of specification using components from 

quality suppliers. The following information is provided to assist you with any repairs required 
within the warranty period. 

 

All warranty repairs on Silvan products are carried out by Silvan dealers. If any 

warranty repairs are required on Silvan products, it is recommended that the product be 
returned to the place of purchase. 

 

It is good practice to keep a record of equipment maintenance both during and after the 

warranty period. 

 
The previous information on warranty coverage explains the extent and limitations of your 

Warranty coverage on Silvan Products. 

 
 

Honda Engine Warranty (If supplied) 

A separate Honda engine manufacturers manual and warranty policy may be supplied if the 
pump has been purchased with an Honda engine attached. 

 

Any engine problem should be reported to your Silvan dealer in the first instance, however, any 
authorised Honda servicing dealer can carry out warranty repairs on the engine provided all the 
details of the purchase and engine are supplied. 

 

 
 

Summary of Contents for APS 101

Page 1: ...21 145 166 IDS 2200 2600 AUSTRALIA HEAD OFFICE NEW ZEALAND 89 Lewis Road Wantirna South 22 Sunshine Ave Te Rapa Victoria 3152 Hamilton 2001 Telephone 61 03 9887 2788 Telephone 64 07 849 6030 Facsimie 61 03 9887 1035 Facsimie 64 07 849 6070 Spare Parts Facsimile 03 9887 1637 www silvanaust com www silvannz co nz MANAPS 2 Rev C 5 06 07 ...

Page 2: ...ng parts or making a warranty claim PUMP MODEL NO _____________________________ PUMP SERIAL NO _____________________________ ENGINE MODEL _____________________________ If Fitted ENGINE SERIAL NO _____________________________ If Fitted SELLINGDEALER ________________________________________________ ADDRESS ________________________________________________ _____________________________ TELEPHONE _____...

Page 3: ...ing from misuse use of incompatible chemicals exceeding machine specifications including overloading impact damage negligence accidental damage or failure to perform recommended maintenance services Any product which has been repaired by other than an authorised Silvan service outlet in a way which in the sole and absolute judgement of Silvan adversely affect its performance or reliability The rep...

Page 4: ...se It is good practice to keep a record of equipment maintenance both during and after the warranty period The previous information on warranty coverage explains the extent and limitations of your Warranty coverage on Silvan Products Honda Engine Warranty If supplied A separate Honda engine manufacturers manual and warranty policy may be supplied if the pump has been purchased with an Honda engine...

Page 5: ... greater than 540 PTO rpm S Do not operate the pump without all the tractor and sprayer or machine safety shields in place Carefully check that PTO and driveline shields are correctly installed if used S Disconnect the tractor PTO or power supply before performing any operation on the pump S Before use of any chemicals refer to the chemical manufacturer s label and safety instructions for safe han...

Page 6: ...ion 16 Delivery Coupling 17 Oil Cap 18 Identification Label PUMP TYPE No OF DIAPHRAGM DELIVERY l min PRESSURE bar p s i POWER HP Max RPM WEIGHT Kg BP 20 15 BP 60 20 BP 75 15 BP 125 20 BP 151 20 BP 171 20 BP 265 20 BP 305 20 2 2 3 3 4 4 6 6 18 7 58 68 117 138 152 252 296 15 215 20 290 15 215 20 290 20 290 20 290 20 290 20 290 0 83 3 3 2 68 6 8 7 8 9 38 14 3 15 8 550 550 550 550 550 550 550 550 7 10...

Page 7: ...Identification Page 6 BP 20 15 BP 75 15 BP 60 20 BP 125 20 BP 151 20 BP 171 20 BP 265 20 BP 305 20 ...

Page 8: ...Identification Page 7 MP20 MP30 MP40 MP40AP P48 APS 31 APS 41 APS 71 ...

Page 9: ...Identification Page 8 APS 96 APS 101 APS 121 APS 145 APS 166 IDS 2200 IDS 2600 ...

Page 10: ...ilter strainer should be approximately 50 mesh The minimum filter area should be 250cm2 per 100 l min rated delivery of the pump eg BP60 20 has a rated delivery of 58 2 l min therefore the minimum filter area would be 250 100 x 58 2 145 5cm2 6 The suction hose between the tank and the filter should have a shutoff valve installed to allow the strainer to be cleaned without emptying the tank The par...

Page 11: ...pressure in the pressure accumulator if fitted fig 3 in accordance with the operating pressure used to spray Adjust according to Table A The pressure can be measured using a car tyre pressure gauge Start Up 1 Ensure the control valve is in the bypass position and any taps not being used are in the closed position For details of the control valve operation you need to refer to the operation manual ...

Page 12: ...gms If broken it is necessary to replace the complete set Continued use with water in the oil will cause serious damage to internal parts of the pump If it is not possible to replace broken diaphragms within one day of failure empty the crankcase of water and pour in oil or diesel oil to stop rust from forming on the internal components Suction The suction system must be inspected to ensure 1 Ther...

Page 13: ...he pump Worn pump inlet outlet valves Pump and hoses vibrating Pump surge chamber pressure incorrectly adjusted or surge diaphragm ruptured Air entering the suction line through loose or damaged fittings Pump valves or valve springs worn or damaged Worn nozzles or capacity of nozzles greater than capacity of the pump Air trapped in filter or suction lines Water in Oil Broken diaphragms OPERATION E...

Page 14: ...NOTES Page 13 ...

Page 15: ...NOTES Page 14 ...

Page 16: ... 89 Lewis Road Wantirna South Victoria 3152 Telephone 61 03 9887 2788 Facsimie 61 03 9887 1035 Spare Parts Facsimile 03 9887 1637 www silvanaust com NEW ZEALAND 22 Sunshine Ave Te Rapa Hamilton 2001 Telephone 64 07 849 6030 Facsimie 64 07 849 6070 www silvannz co nz ...

Reviews: