background image

 

 

 

 
 

 

 
 
 

 

 
 
 
 
 
 

 
 
 
 
 

 
 

 
 

OPERATION

 

Initial Start Up:

 

After satisfying the installation requirements, the unit is ready to start.  The unit will start when the power cord is connected to the 
required power source.  If the compressor does not start when the unit is initially plugged in, check to make sure that the 
temperature control is not in the 'off' position.  Allow the unit to run a minimum of two hours before loading it with product.  When 
loading the unit with product, take care not to block the air flow at the back of the cabinet as this would affect the performance of the 
cabinet. 
 

Temperature Control

 

The  Temperature  Control is  located on  the back  of  the cabinet  and  is  factory  set  to maintain  an average cabinet  temperature of 
approximately 0 Deg F.  To obtain colder temperatures, press and hold the set button until the set point value flashes.  Use the up or 
down arrow buttons to change the value and then press the set button again.  Allow the unit a minimum of one hour to respond to a 
control setting adjustment. 
 

Defrost:

 

Your Silver King unit is an automatic defrost unit.  No additional plumbing is required.  Automatic defrosting is accomplished by a 
defrost heater and timer.  Defrost water is collected in a pan located in the compressor compartment where it is evaporated into the 
room air.  It is important that the unit be level so the condensate can drain properly. 
 

MAINTENANCE

 

Preventative maintenance is minimal although these few steps are very important to continued operation and maximizing the life of 
the appliance. 
 

Cabinet Surfaces:

 

The cabinet interior is aluminum and the exterior is stainless steel.  These surfaces should be cleaned periodically with a solution of 
warm water and mild soap.  After cleaning the surfaces, they should be rinsed with clean water and wiped dry with a soft cloth.  
Stainless steel cleaners can be used on the exterior.  Should a surface become stained, do not attempt to clean with an abrasive 
cleaner or scouring pad.  Use a soft cleanser and rub with the grain of the metal to avoid scratching the surface.   Always rinse well 
and dry after cleaning.  Do not use chlorinated cleaners. 
 

Condenser 

Periodically, accumulated dust must be removed from the condenser. First, disconnect the unit from the power supply. To clear the 
dust, vacuum or brush the condenser at the bottom rear of the cabinet. This will need to be done regularly to maintain the 
compressor warranty! 

WARNING:  The condenser fins are very sharp, use caution when cleaning the condenser. 

 

Door Gasket

 

The Door Gasket will collect dirt and should be wiped clean with a warm, mild soapy water solution to extend its life and assure 
maximum cabinet performance and life. 

MODEL 

SERIAL NO. 

DATE INSTALLED 

Summary of Contents for SKF27A-ES

Page 1: ...cations Subject to Change Without Notice 1600 Xenium Lane North Minneapolis MN 55441 3787 Phone 763 923 2441 Technical Manual Replacement Parts List Freezer FORM NO 45266 SK REV E 08 2021 MODEL SKF27A...

Page 2: ...ed at altitudes higher than 2000 meters Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance Do not exceed the maximum load capacity of 50 pounds per sh...

Page 3: ...lf system allows for easy adjustment to suit your needs Door Adjustment and Swing Should the door ever require straightening loosen the screws on the hinges square the door with the cabinet and retigh...

Page 4: ...here it is evaporated into the room air It is important that the unit be level so the condensate can drain properly MAINTENANCE Preventative maintenance is minimal although these few steps are very im...

Page 5: ...4...

Page 6: ...5...

Page 7: ...14 01 CASTER KIT 2 10314 100 CASTER KIT 3 10314 63 16 HINGE BOTTOM 24549 17 HINGE TOP 27181 18 PIN TOP HINGE 22415 19 KIT COMPRESSOR W ELECTRICALS 115V 60HZ 11700 2 20 KIT ELECTRICALS 115V RELAY OVERL...

Page 8: ...7...

Page 9: ...pare the multimeter s reading to Table 1 Analyze Results If the resistance and temperature are similar then the thermistor is working properly and does not need to be replaced If the resistance and te...

Page 10: ...and or economic loss This Equipment warranty is in lieu of all other warranties express or implied are hereby disclaimed and excluded including those of merchantability and fitness for a particular pu...

Page 11: ...include but are not limited to temperature control adjustments temperature indicator calibrations coil and filter cleaning or condensate drain cleaning A second service call for a related failure is n...

Page 12: ...KING SHALL HAVE NO OBLIGATION OR LIABILITY FOR CONSEQUENTIAL OR SPECIAL DAMAGES INCLUDING BUT NOT LIMITED TO INDIRECT PUNITIVE DAMAGES LOSS OF USE LOSS OF PRODUCT DOWNTIME OR LOST PROFITS ARISING OUT...

Reviews: