background image

 

REPLACEMENT PARTS LIST – SKF27A-ES 115V 

ITEM NO.

PART DESCRIPTION

PART NO.

1

DOOR ASSEMBLY (STANDARD)

38361

2

DOOR GASKET KIT

10310-75

3

TEMPERATURE INDICATOR

22409

4

PILASTER 20"

24600

5

SHELF

35835

6

SHELF SUPPORT

99530

7

POWER CORD 115V

32199

DEFROST PROBE EVAPORATOR
TEMPERATURE PROBE

9

DEFROST HEATER EVAPORATOR

47076-SK

10

CAPILLARY TUBE EVAPORATOR

99035

11

EVAPORATOR COIL

38337

12

EVAPORATOR FAN MOTOR  115V/230V

39577

13

AIR CURTAIN ASSEMBLY

38353

14

   FILTER CONDENSER (OPTIONAL)

31221

CASTER KIT 1 5/8"

10314-01

CASTER KIT 2"

10314-100

CASTER KIT 3"

10314-63

16

HINGE BOTTOM

24549

17

HINGE TOP

27181

18

PIN TOP HINGE

22415

19

KIT COMPRESSOR W/ ELECTRICALS 115V/60HZ

11700-2

20

KIT ELECTRICALS 115V (RELAY, OVERLOAD, CAPACITOR)

11701-2

21

GROMMET COMPRESSOR MOUNT

20481

22

WASHER COMPRESSOR MOUNT

22401

23

HAIRPIN CLIP COMPRESSOR MOUNT

98106

24

DRIER

22677

25

ELECTRONIC TEMPERATURE CONTROL 115V (PROGRMD)

45768

26

CONDENSATE PAN ASSEMBLY

38379

27

CONDENSER FAN MOTOR  115V/230V

39577

28

CONDENSER COIL

39259

29

REAR PANEL

45250

30

KIT 4" STANDOFF BRACKETS (OPTIONAL) (NOT SHOWN)

10327-89

31

TONG HOLDER (OPTIONAL) (NOT SHOWN)

34997

FORM 45265 REV C

8

38822

15

WHEN ORDERING REPLACEMENT PARTS, PLEASE PROVIDE MODEL AND SERIAL NUMBERS. 

Summary of Contents for SKF27A-ES

Page 1: ...cations Subject to Change Without Notice 1600 Xenium Lane North Minneapolis MN 55441 3787 Phone 763 923 2441 Technical Manual Replacement Parts List Freezer FORM NO 45266 SK REV E 08 2021 MODEL SKF27A...

Page 2: ...ed at altitudes higher than 2000 meters Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance Do not exceed the maximum load capacity of 50 pounds per sh...

Page 3: ...lf system allows for easy adjustment to suit your needs Door Adjustment and Swing Should the door ever require straightening loosen the screws on the hinges square the door with the cabinet and retigh...

Page 4: ...here it is evaporated into the room air It is important that the unit be level so the condensate can drain properly MAINTENANCE Preventative maintenance is minimal although these few steps are very im...

Page 5: ...4...

Page 6: ...5...

Page 7: ...14 01 CASTER KIT 2 10314 100 CASTER KIT 3 10314 63 16 HINGE BOTTOM 24549 17 HINGE TOP 27181 18 PIN TOP HINGE 22415 19 KIT COMPRESSOR W ELECTRICALS 115V 60HZ 11700 2 20 KIT ELECTRICALS 115V RELAY OVERL...

Page 8: ...7...

Page 9: ...pare the multimeter s reading to Table 1 Analyze Results If the resistance and temperature are similar then the thermistor is working properly and does not need to be replaced If the resistance and te...

Page 10: ...and or economic loss This Equipment warranty is in lieu of all other warranties express or implied are hereby disclaimed and excluded including those of merchantability and fitness for a particular pu...

Page 11: ...include but are not limited to temperature control adjustments temperature indicator calibrations coil and filter cleaning or condensate drain cleaning A second service call for a related failure is n...

Page 12: ...KING SHALL HAVE NO OBLIGATION OR LIABILITY FOR CONSEQUENTIAL OR SPECIAL DAMAGES INCLUDING BUT NOT LIMITED TO INDIRECT PUNITIVE DAMAGES LOSS OF USE LOSS OF PRODUCT DOWNTIME OR LOST PROFITS ARISING OUT...