2
Electrical Connections
Be sure to check the data plate, located on the liner of the cabinet, for required voltage prior to connecting the unit to power. The
specifications on the data plate supersede any future discussion.
The standard freezer is equipped with an eight (8) foot power cord that requires a 115 Volt, 60 Cycle, 1 Phase properly grounded
electrical receptacle. The power cord comes with a 3 prong plug for grounding purposes. Any attempt to cut off the grounding
spike or to connect to an ungrounded adapter plug will void the warranty, terminate the manufacturers responsibility and could result
in serious injury.
The circuit must be protected with a 15 or 20 ampere fuse or breaker. The unit must be isolated on a circuit and not plugged into an
extension cord.
OPERATION
Initial start up
After satisfying the installation requirements, the freezer is ready to start. The Compressor will start when the power cord is
connected to the required power source. If the Compressor does not start when the unit is initially plugged in, check to make sure
that the Temperature Control is not in the off position. Allow the unit to run for two hours before loading it with product. When
loading the unit with product, take care not to block the air flow in the cabinet as this would affect the units performance.
Temperature Control
The Temperature Control is located on the back of the cabinet and is factory set to maintain an average cabinet temperature of
approximately 0 Deg F. To obtain colder temperatures, press and hold the set button until the set point value flashes. Use the up
or down arrow buttons to change the value and then press the set button again. Allow the unit a minimum of one hour to respond to
a control setting adjustment.
Defrost
Your Silver King freezer is an automatic defrost unit and no additional plumbing is required. Automatic defrosting is accomplished
by a defrost heater and timer. Frost buildup on the Evaporator Coil is cleared at five hour intervals. Defrost water is collected in a
pan located in the compressor compartment where it is evaporated into the room air. It is important that the unit be installed level to
allow proper drainage of the condensate water.
MAINTENANCE
Preventative maintenance is minimal although the following few steps are very important to continued operation and maximizing the
life of the appliance.
Cabinet Surfaces
The cabinet interior is aluminum and the exterior is stainless steel. These surfaces should be cleaned periodically with a solution of
warm water and mild soap, rinsed and wiped dry with a soft cloth. A good stainless steel cleaner can also be used. Should a surface
become stained, do not attempt to clean with an abrasive cleanser or scouring pad. Use a soft cleanser and rub with the grain of the
metal to avoid scratching the surface. Do not use chlorinated cleaners. Always rinse well and dry after cleaning.
Condenser
Periodically, accumulated dust must be removed from the condenser. First, disconnect the unit from the power supply. To clear
the dust, vacuum or brush the condenser at the rear of the cabinet. This will need to be done regularly to maintain the compressor
warranty!
Drawer Gasket
The Drawer Gasket will collect dirt and should be wiped clean with a warm, mild soapy water solution to extend its life and assure
maximum cabinet performance and life.
MODEL
SERIAL NO.
DATE INSTALLED
Summary of Contents for SKF72D/C10
Page 8: ...7...
Page 9: ...8...
Page 10: ...9 WHEN ORDERING REPLACEMENT PARTS PLEASE PROVIDE MODEL AND SERIAL NUMBERS...
Page 11: ...10...
Page 12: ...11...