7. Preparation
7.1
Setting up the device
Place the device on a dry, level and heat-re-
sistant surface.
7.2
Requirements on the
film/bags
-
You can use tubular film or complete
bags.
-
The film must not be wider than 28 cm.
-
The film must be provided with dots/
knobs or grooves on one side. Smooth
films are not suited for sealing.
-
Thickness should be between 0.17 and
0.29 mm (170 - 290
).
-
When buying the film, check the temper-
ature range it is suited for. The ideal
range is between -20 °C and +110
|
°C.
Such films can be deep-frozen or boiled.
The film included in the delivery is suited
for this application.
-
You will find those data on the package
of the film or bag.
7.3
Producing a bag
If you use finished bags, these steps do not
apply.
1. Unwind the length of film from the roll
you require for your bag. Regarding the
length of the bag, remember that a
space of approx. 6 cm towards the top
should be left after filling.
2. Use scissors to cut the piece of film as
straight as possible.
3. For sealing the bag (see “Seal the bag”
on page 7).
8. Use
Every active function can be cancelled im-
mediately by pressing the button
|
3
.
WARNING! Risk of material
damage!
~
Observe the specified operating time of
the device. After the sealing or vacuum-
ing process, the device must cool down
for at least 80 seconds.
8.1
Fill the bag
CAUTION:
~
No food or liquids must be present at
the top edge, where you want to seal
the bag. That area must be clean and
dry. Otherwise, it is impossible to pro-
duce a proper welding seam.
•
Fill the bag only up to a level of 6 cm
below the top edge.
8.2
Seal the bag
1. Smooth the bag where it is to be
sealed.
2. Open the lid
|
11
. If necessary, press the
buttons
|
8
first.
3.
Figure A:
place the bag in the device.
For this purpose, the end of the film
must be positioned shortly in front of the
rear limitation webs
|
12
and the lateral
limitation webs
|
15
.
4. Ensure again that there are no creases
in the film - especially in the area above
the welding wire
|
14
.
5. Close the lid
|
11
.
6.
Figure B:
use both hands to press firm-
ly on the edges of the lid
|
11
. They must
engage audibly.
__CPE281169_Folienschweissgeraet_B4.book Seite 7 Montag, 19. September 2016 3:02 15
Summary of Contents for SFS 110 B2
Page 15: ...13 GB __CPE281169_Folienschweissgeraet_B4 book Seite 13 Montag 19 September 2016 3 02 15 ...
Page 28: ...26 HU __CPE281169_Folienschweissgeraet_B4 book Seite 26 Montag 19 September 2016 3 02 15 ...
Page 51: ...49 CZ __CPE281169_Folienschweissgeraet_B4 book Seite 49 Montag 19 September 2016 3 02 15 ...
Page 76: ...__CPE281169_Folienschweissgeraet_B4 book Seite 74 Montag 19 September 2016 3 02 15 ...
Page 77: ...__CPE281169_Folienschweissgeraet_B4 book Seite 75 Montag 19 September 2016 3 02 15 ...