4
GB
Specification
Impact Driver:
Technology: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.8V, Li-Ion
No load speed: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0-2400min
-1
Max torque: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100Nm
Compatible bits: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ¼"(6.35mm)
Max bolt capacity: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . M10
Weight:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.90kg
Battery:
Cell type: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Li-Ion
Voltage: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.8V, DC
Capacity: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3Ah
Charger:
Input power:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100–240V~ 50-60Hz, 9W
Output power:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15V DC, 400mA
Ingress protection: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IPX0
Protection class:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
As part of our ongoing product development, specifications of
Silverline products may alter without notice.
Sound and vibration information:
Sound pressure L
PA
: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60.21dB(A)
Sound power L
WA
:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71.21dB(A)
Uncertainty K:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3dB
Weighted vibration a
h
:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.962m/s
2
Uncertainty K:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5m/s
2
The sound intensity level for the operator may exceed 85dB(A)
and sound protection measures are necessary.
Original Instructions
Technical Abbreviations Key
WARNING
: Always wear ear protection where the sound level exceeds 85dB(A)
and limit the time of exposure if necessary. If sound levels are uncomfortable, even with
ear protection, stop using the tool immediately and check the ear protection is correctly
fitted and provides the correct level of sound attenuation for the level of sound produced
by your tool.
WARNING
: User exposure to tool vibration can result in loss of sense of touch,
numbness, tingling and reduced ability to grip. Long-term exposure can lead to a chronic
condition. If necessary, limit the length of time exposed to vibration and use anti-vibration
gloves. Do not operate the tool with hands below a normal comfortable temperature, as
vibration will have a greater effect. Use the figures provided in the specification relating to
vibration to calculate the duration and frequency of operating the tool.
Sound and vibration levels in the specification are determined according to EN60745
or similar international standards. The figures represent normal use for the tool in
normal working conditions. A poorly maintained, incorrectly assembled, or misused tool,
may produce increased levels of noise and vibration.
www.osha.europa.eu
provides
information on sound and vibration levels in the workplace that may be useful to domestic
users who use tools for long periods of time.
Description of Symbols
The rating plate on your tool may show symbols. These represent important information
about the product or instructions on its use.
Wear hearing protection.
Wear eye protection.
Wear breathing protection.
Wear head protection.
Wear hand protection.
Read instruction manual.
DO NOT incinerate batteries!
Environmental Protection. Waste electrical products should not be disposed
of with household waste. Please recycle where facilities exist.
Check with your local authority or retailer for recycling advice.
Internal time lag fuse with a maximum current of 3.15A.
Charger: Class II construction (double insulated for additional protection)
Caution!
Conforms to relevant legislation and safety standards.
For indoors use only!
Li-ion battery cells are recyclable and should not be disposed of with
household waste. Please recycle where facilities exist. Check with your local
authority or retailer for recycling advice
V
Volts
~
Alternating current
A
Ampere
n
0
No load speed
Hz
Hertz
W, kW
Watt, kilowatt
/min or min
-1
(revolutions or reciprocation) per minute
Introduction
Thank you for purchasing this Silverline tool. This manual contains information
necessary for safe and effective operation of this product. This product has
unique features and, even if you are familiar with similar products, it is necessary
to read this manual carefully to ensure you fully understand the instructions.
Ensure all users of the tool read and fully understand this manual.
Li-ion
T3.15A
652640_Z1MANPRO1.indd 4
20/07/2016 09:02