If the voltage
≥
4.3V, the following URC will be reported:
OVER-VOLTAGE WARNNING
If the voltage < 3.4V, the following URC will be reported, and the module will be automatically powered down.
UNDER-VOLTAGE POWER DOWN
If the voltage > 4.4V, the following URC will be reported, and the module will be automatically powered down.
OVER-VOLTAGE POWER DOWN
At this moment, AT commands can not be executed any more. The status light will be powered off at this time.
4.2.2.4.
Over-temperature or Under-temperature Power down
The module will constantly monitor the temperature of the module,
If the temperature > +80
℃
, the following URC will be reported:
+CMTE: 1
If the temperature < -30
℃
, the following URC will be reported:
+CMTE:-1
If the temperature > +85
℃
, the following URC will be reported, and the module will be automatically powered
down.
+CMTE: 2
If the temperature <
-40
℃
, the following URC will be reported, and the module will be automatically powered
down.
+CMTE:-2
At this moment, AT commands can not be executed any more. The status light will be powered off at this time.
Note
:
The default temperature detect is disabled, AT command “AT+CMTE” could be used to read the
temperature when the module is running.For details please refer to document [1].
4.2.3.
Reset Function
SIM2000S also has a RESET pin (pin 16) used to reset the module. This function is used as an emergency reset
only when AT command “AT+CPOWD=1” and the POWER_ON pin has no effect. User can pull the RESET pin
to ground, and then the module will be reset.
The external isolation of this pin is necessary. Following figure is internal circuit of the RESET pin.
Figure 12: Reset circuit
SIM2000S_Hardware_Design_V1.00
22
2014-02-27