SIM2 DOMINO 55M
RS-232C CONTROL SPECIFICATIONS
1. Introduction
This document describes the communication and data formats used to control SIM2 DOMINO 55M via RS-
232C port.
2. Connection
Switch off your Personal Computer and DOMINO 55M before connecting RS 232C cable.
Use a standard serial cable with 9 pin female to the Personal Computer and 9 pin male to the DOMINO 55M:
pin 2 connects to pin2, pin 3 to pin 3 and pin 5 to pin 5.
SIM2 DOMINO 55M RS-232C Port is described as follows.
SIM 2 DOMINO 55M E-LINK RS-232C Control Port:
Pin No
Signal
Definition
1 N/A Not
used
2 TD Transmit
data
3 RD Receive
data
4 N/A Not
used
5 GND
Ground
6 N/A Not
used
7 N/A Not
used
8 N/A Not
used
D-SUB 9-pin
(female)
5
1
9
6
9 N/A Not
used
Switch on the Personal Computer and, after start up, switch on the DOMINO 55M.
Load a suitable communication software onto your Personal Computer, and set the Serial Port Parameters as
shown below.
Communication Parameters:
Parameter
Value
Transfer Rate
19200 bps
Data Bits
8
Parity Bit
None
Stop Bit
1
Flow Control
None
Set Send Mode and Read Mode to HEX.
3