ENGLISH
4.
ELECTRICAL PLUGGING AND ADJUSTING THE DISK ROTATION SENSE
Upon receipt of the machine, make sure the network electrical tension is adequate before plugging the machine. The
electrical tension is to be found on the voltage indication next to the switch of the machine.
ATTENTION: Never plug the machine to electricity, in case the network power tension is not the adequate
as the engine would undergo irreparable damages.
Once you have realised the previous steps and before placing the disk and manipulate the motor, it is
necessary to check and adjust the rotation of the motor axis correctly, you have to plug the machine to the electricity
and start it up, watching the rotation direction that must be clockwise.
If necessary and with three-phase motors, you can change the rotation direction swapping the two phase wires in the
aerial or in the peg of the feeding extension cord.
ATTENTION: Never manipulate power supply cables or any other electrical equipment on the machine
before you unplug the machine from electricity.
ATTENTION: Unplug the machine from the network before proceeding to change
the position of the bridge plates on the engines. You should also proceed to change
the stickers indicating the supply voltage, so there will always be indicated on the
machine rated voltage.
5.
ELECTRICAL EQUIPMENT
The electrical equipment of table saw has an IP54 protection degree.
The power supply on this machine has a low minimal tension coil to avoid any unexpected starting-up of the
machine. When there is a power cut or a fall of tension that causes the machine to stop, and once the normal power
conditions have been re-established, the motor does not start until the green button is pressed.
ATENCIÓN: The three-phase SPADA MKNO models leave the factory prepared to work at 400V.
ATENCIÓN: When necessary to use a three-phase power tension at 230V, we need to swap the positions of
the bridge plates in the motor terminals box, as indicated in the following figure:
ATENCIÓN: The extension cable used to feed the machine needs to have a minimum section on the table as
shown below
MOTOR
CONEXIÓN
0
‐
10
m
10
‐
20
m
20
‐
30
m
2,2
Kw
3
kw
1
Phase/
Mono.
110V
50/60Hz
2,5
mm2
6
mm2
10
mm2
1
Phase/
Mono.
230V
50/60Hz
2,5
mm2
2,5
mm2
4
mm2
3
Phase/
Trif.
230V
50/60Hz
2,5
mm2
2,5
mm2
4
mm2
3
Phase/
Trif.
400V
50/60Hz
2,5
mm2
2,5
mm2
2,5
mm2