5
Ioncell
5201128 Rev. D
In-line Ioncell connections: An in-line manifold is mounted within the emitter pin
grid area of ionizer. The in-line manifold allows for multi-tube configurations for
locations which have been previously inaccessible for other ionizers. The input and
output connectors both take 1/4” OD tubing. Insert tubing into connector and run
tube to desired location, or, use a 2-way splitter to direct ionization to two different
locations. For optimal performance, use shortest tube lengths possible. Excessive
tube lengths will increase discharge times.
NOTE
– Tubing must have the same inside diameter on both sides of the
in-line manifold.
A +5 VDC (TTL level) alarm output is provided for remote monitoring of the
ionizer operating condition. ALARM+ goes high (+5 VDC) on alarm. See Figure
2 for complete connection diagram.
Optional Airflow Switch for In-line Ioncells: The airflow switch replaces the power
cable between the ionizer and power supply. It includes two 1/4” tubing connectors,
labeled “AIR INPUT” for the compressed air supply and “AIR OUTPUT” to be
connected to the ionizer. The In-line Ioncell will switch power to the ionizer off
when compressed air is not being fed to the assembly.
Figure 1. Output Tube Configurations (single and split)