GB
7.3.2
Graphics
tab
The
Graphics
tab graphically shows the operation as function over time.
-
Yellow: the positive and negative ion current.
-
Blue: the efficiency of the bar
If coupled with a sensor bar:
-
Green: the average (residual) charge measured by the sensor bar.
If the screen is clicked, the screen will “freeze”, and display
On hold.
Clicking the screen again
will display the current value.
7.3.3 Action log tab
In the
Action log
tab, the changing status of the bar is logged step-by-step. This is indicated
including the date and time the status change occurred. Main messages are:
-
HV OK
: the bar is turned on and is functioning properly.
-
HV NOT OK
: the bar is turned off or the HV doesn’t function properly.
-
CLEAN BAR
: the efficiency has dropped below the clean bar warning level.
7.3.4
Data log
tab
In the
Data log
tab, all available measurement data of the bar is logged at fixed times.
If the parameter
Datalogging
is activated, these values will also be saved in the log file of the
Manager. The interval between logging is determined by the setting in the Manager IQ Easy.
See the user manual of the Manager in Chapter 6.6.3
Main measurement values:
- I-: the output current of the negative high-voltage.
- I+: the output current of the positive high-voltage.
- Eff: the efficiency of the bar
7.4 Causes for overloading
Causes for overloading of the high voltage may be due to:
- Contamination of the anti-static bar.
- Direct contact between conductive material and emitters.
- The anti-static bar is mounted too close to conductive (machine) parts.