background image

* Covers an extended distance and large area coverage with ionized air. 
* Variable speed fan with wide range of air flow. 
* Integrated task lights (9 watt twin tube) 
* Inherently balanced ion output. 
* Expediently ion emitter cleaner. 
* Ionization indicator lamp. 
* Durable, electrically grounded metal enclosure. 
* Hanging installation and economize space greatly   
 

SECTION 3 Specifications

 

Unit Part Number:           OVERHEAD-120VAC    OVERHEAD-230VAC 
               
Line Voltage:                   120 VAC 60 Hz     230 VAC 50Hz 
 
Current Draw:                                      Max. 2 Amp                1 Amp 
                                                                 
 
Air Volume Output:                            Fan Speed                  Flow 
                                Low               2*35 CFM 
                                High              2*70 CFM 
 
Air Velocity                                        Fan Speed          1ft.    2ft.    3ft.    4ft.   
                             Low           250   200   150   125 
                             High          500   400   300   250 
                                                  Velocity in FPM measured at center line of air stream 
 
Air Flow Characteristics:              2

1

/

2

’ x 5’ Area Coverage(750

mm

×1500

mm

 
Operating Temperature:                      32

(0

)      122

(50

)

℉ ℃

 

 
Ozone Production:               0.01 ppm measured 6’’in front of unit,       
                                                                fan low. 
 
Audible Noise:                                  Fan Speed 
                                                              Low        45dB 
                               High   50dB 
                                                              Measured 2 ft. from unit. 
 
Enclosure:                                          Steel   

Summary of Contents for OVERHEAD Series

Page 1: ...OVERHEAD is a two Fan unit designed to provide targeted coverage for electrostatic problems MATTERS FOR DAILY INSPECTION Clean high voltage needles Verify grounding connection Inspect equipment for da...

Page 2: ...y The high voltage AC is applied to a circular arrangement of stainless steel ion emitter points which results in an intense alternating electric field at the tip of the emitter points It is this elec...

Page 3: ...ations Unit Part Number OVERHEAD 120VAC OVERHEAD 230VAC Line Voltage 120 VAC 60 Hz 230 VAC 50Hz Current Draw Max 2 Amp 1 Amp Air Volume Output Fan Speed Flow Low 2 35 CFM High 2 70 CFM Air Velocity Fa...

Page 4: ...3 15 300mm Tp2 1 5 tp6 3 5 p10 7 0 tp14 11 0 300mm Tp3 1 5 tp7 3 5 tp11 7 0 tp15 11 0 300mm blower Tp4 5 5 tp8 8 5 tp12 11 0 tp16 15 0 1 Offset voltage and discharge time determined as per ESD Associa...

Page 5: ...The BLOWER OVERHEAD should be placed approximately 1 to 3 feet from the critical work area or objects to be neutralized It should be positioned to cover as much of the area as possible with the ionize...

Page 6: ...he time required to neutralize a static charge on an item in the air stream depends on many factors Two important factors are distance to ionizer and air velocity Air ions constantly neutralize each o...

Page 7: ...is stubborn wash the filter in mild soap and water then rinse Blot the filter dry with paper towels and allow to dry Install filter on air inlet and secure by snapping the filter retainer in place IMP...

Page 8: ...ting value can be changed with difference of temperature humidity and ambient environment Do not try to determine ion balance by holding a static meter in the ionized air stream This will result in s...

Page 9: ...SECTION 8 How to hang...

Reviews: