SECTION 4 Safety 

1.

 

Read instruction manual before installing or operating device. 

2.

 

This unit is equipped with a 3-prong grounding plug and must be plugged into a 
3-terminal grounded receptacle. Do not defeat the grounding by modifying the 
plug or using an ungrounded 3-prong adapter, If an extension cord is necessary, 
use only a 3-wire extension cord that provides grounding. 

3.

 

Do not insert objects through intake or outlet grille. 

4.

 

Do not operate unit in flammable or explosive atmospheres. 

5.

 

Internal repairs or servicing must be done by qualified personnel. 

 

SECTION 5 Installation 

The BLOWER OVERHEAD is designed for permanent operation. The overhead 
blower can be used in permanent operation by hanging it to a sturdy flat surface such 
as a wall or under a shelf.   
 
For extremely dirty environments, an optional air filter may be installed. The air 
filter consists of a filter retainer and an air filter element. 
 
The BLOWER OVERHEAD should be placed approximately 1 to 3 feet from the 
critical work area or objects to be neutralized. It should be positioned to cover as 
much of the area as possible with the ionized air stream.   
 
The BLOWER OVERHEAD, part number OVERHEAD-120VAC, requires 120 
VAC 60 Hz for proper operation. The unit must be grounded for safe operation. Plug 
the unit into a standard 3-terminal grounded receptacle. If an extension cord is 
necessary, use only a 3-wire extension cord that provides grounding. 
 
The BLOWER OVERHEAD, part number OVERHEAD-230VAC,requires 230 
VAC 50 Hz for proper operation. The unit must be grounded for safe operation. The 
unit comes with line cord, without plug. A plug must be installed on the line cord for 
operation. Installation of the plug must be performed by qualified personnel. The 
color code for wiring the plug is as follows: Brown – Line; Blue – Neutral; 
Green/Yellow – Ground. 
 
Under the unclean environment, please set the filtration attached. 
This filtration includes a fixture and a carbon filter. 
Put the carbon filter inside the fixture, then fix the fixture to the plastic shield. Press 

Summary of Contents for OVERHEAD Series

Page 1: ...OVERHEAD is a two Fan unit designed to provide targeted coverage for electrostatic problems MATTERS FOR DAILY INSPECTION Clean high voltage needles Verify grounding connection Inspect equipment for da...

Page 2: ...y The high voltage AC is applied to a circular arrangement of stainless steel ion emitter points which results in an intense alternating electric field at the tip of the emitter points It is this elec...

Page 3: ...ations Unit Part Number OVERHEAD 120VAC OVERHEAD 230VAC Line Voltage 120 VAC 60 Hz 230 VAC 50Hz Current Draw Max 2 Amp 1 Amp Air Volume Output Fan Speed Flow Low 2 35 CFM High 2 70 CFM Air Velocity Fa...

Page 4: ...3 15 300mm Tp2 1 5 tp6 3 5 p10 7 0 tp14 11 0 300mm Tp3 1 5 tp7 3 5 tp11 7 0 tp15 11 0 300mm blower Tp4 5 5 tp8 8 5 tp12 11 0 tp16 15 0 1 Offset voltage and discharge time determined as per ESD Associa...

Page 5: ...The BLOWER OVERHEAD should be placed approximately 1 to 3 feet from the critical work area or objects to be neutralized It should be positioned to cover as much of the area as possible with the ionize...

Page 6: ...he time required to neutralize a static charge on an item in the air stream depends on many factors Two important factors are distance to ionizer and air velocity Air ions constantly neutralize each o...

Page 7: ...is stubborn wash the filter in mild soap and water then rinse Blot the filter dry with paper towels and allow to dry Install filter on air inlet and secure by snapping the filter retainer in place IMP...

Page 8: ...ting value can be changed with difference of temperature humidity and ambient environment Do not try to determine ion balance by holding a static meter in the ionized air stream This will result in s...

Page 9: ...SECTION 8 How to hang...

Reviews: