5200992 Rev F
27
Sensor:
Lights (orange) to indicate if a web monitor is connected to
the system and active. When this indicator is lit, the system is in
closed-loop feedback and the web monitor is controlling the balance
of ionization.
Bar On:
Lights (green) when static neutralizing bar is active.
Fault:
Lights (red) to indicate faulty condition of static bar, power
supply or high voltage connections. Power will have to be turned off
to clear the fault. When fault is cleared and power is restored, the
fault light will be extinguished.
Clean Bar:
Lights (yellow) to indicate need to clean static bar. Clean
Bar indicator may light with low ion output (dirt build-up on ion
emitters) or high output current (conductive contamination on face of
bar). See Maintenance section for static bar cleaning details.
Mode:
The indicator next to the type of bar connected will light
(green).
“Speed”, “Hybrid” or “Distance” will be indicated.
In cases where two different types of bars are connected, the system
will set for the safer of the two operating voltages and light the
corresponding Mode indicator.
The Mode indicators (along with the Clean Bar indicator) indicate the
Power Supply number
during start-up of the power supply.
Output:
The output indicators range from
“Low” to “High” in 10 steps
(2-red, 3-yellow, 5-green) and light to indicate the system relative ion
output. The output will normally be in the high range. Low output
generally indicates the need to clean the static bar. See
Maintenance section for static bar cleaning details.
6.2 Power Supply Operators
Initial Calibration:
Is a momentary switch located in the face label
above
“Initial Calibration” on the label. Pressing the face label firmly
above
“Initial Calibration” initiates the calibration sequence and sets
the relative nominal ion output for the system.
The Initial Calibration button is also used to change the
Power
Supply number
. This number is used in software to identify the
power supply in systems that contain multiple power supplies and
include a Communication Module.