6.5 Web Monitor Operation (optional)
A. Switch the
“Power” switch on web monitor to the “On” (1)
position.
B. The web monitor display will briefly display its firmware revision
level and then will begin communications with the PerforMAX IQ
system. Communication will be indicated by a flickering of the
(green)
“Remote Communications Status” indicator on the web
monitor.
The power supply will indicate use of the web monitor by lighting the
“Sensor” indicator on the face of the power supply.
If the system is new, it may be necessary to change the Sensor
Spacing Distance and/or Feedback status in the web monitor control
box to agree with the actual installed sensor configuration. See
Sensor Spacing Distance / Feedback below.
C. During operation, the web monitor will display the web static
charge, in kilovolts, for each sensor. If no sensor is connected, it
will display
“no sensor”.
D. The web static charge value is used by the PerforMAX IQ power
supply to provide closed-loop feedback. The power supply
adjusts its operation to null the web static charge value,
neutralizing the static charge. If multiple probes are used, the
web static charge value from all probes will be averaged.
E. The operating parameters for the web monitor may be set at any
time using the
“Menu” and up (+) arrow or down (-) arrow buttons
on the face label of the web monitor.
Sensor Spacing Distance
(default: 25mm [1
”])
Allows adjustment of the distance between the web and the
sensor probe. Adjusting the sensor spacing distance allows for
calibrated operation at one of three distances: 25mm [1
”], 50mm
[2
”] and 75mm [3”]. The web monitor compensates for each
sensor probe individually. The sensor spacing distance may be
set for each individual probe.
Zero Sensor
(default: no)
Used to null out any differences between the web monitor and
sensor probe. These differences can also be caused by sensor
probe wire re-termination. The sensor is typically zeroed (YES)