49
3.3
CLEANING THE BOILER
(fig. 12)
The boiler body and flue should be
cleaned at the end of each season.
To clean the boiler, simply remove the
burner-holding plate and the cleaning
plate with their insulation and protec-
tion panels; this operation gives easy
access to the three front pockets and
the combustion chamber. Before pro-
ceeding to clean the and
“1R 6 OF - 2R
6 ÷ 9 OF/OF S/GT OF”
models, the
baffles must be removed.
Once maintenance has been comple-
ted, reposition the baffles. Use the pig
to clean the smoke pipes.
NOTE: Preventive maintenance must
be carried out by authorized techni-
cal staff.
3.4
USER
WARNINGS
When faults occur and/or the equip-
ment does not operate correctly, turn
it off, without attempting to make any
repairs or take direct action.
For any operation only contact the
authorised technical personnel in your
area.
Fig. 12
“1R OF” boiler
“2R OF/OF S/ GT OF” boilers