background image

2683

5

GB

3.3 ELECTRICAL WIRING

Fig. 8

E9040

A

C

A

R

R

IED

-O

U

T

 I

N

 T

H

F

A

C

T

O

R

Y

7 pin plug

7 pole socket

Black

White

Blue

Capacitor

Burner-earth 

T6A

C

O

N

T

R

O

L

 B

O

X

5

5

5

SE

~

 50Hz 230V

D1847

Photoresistance

Oil valve

Hour counter
(230V - 0.1A max.)

Regulating
thermostat

Remote lock-out lamp
(230V - 0.5A max.)

Ignition

electrodes

Start thermostat

Heater

L

N

PE

Motor

Main switch 

Limit thermostat
with manual
resetting

TESTING

Check  the  shut-down  of  the
burner  by  opening  the  ther-
mostats.

CONTROL BOX

To  remove  the  control-box
from the burner, loosen screw
(

A,

fig. 8) and pull to the arrow

direction,  after  removing  all
components,  the  7  pin  plug
and earth wire.

NOTES:

– Wires of 1 mm

2 section

.

– The  electrical  wiring  carried  out  by  the  installer

must be in compliance with the rules in force in the
Country.

DO NOT EXCHANGE  NEUTRAL WITH PHASE

WARNING

ACCESS TO THE PHOTORESISTANCE
(See fig. 9)

The

photoresistance is fitted directly into the con-

trol-box

 (underneath the ignition-transformer)

 on a

plug-in support.

Ignition
trasformer

Fig. 9

E9102

Photoresistance

Summary of Contents for 8099000

Page 1: ...iften Installation use and maintenance instructions Oil burners Br leurs oul Stookoliebranders CODE MODEL MODELE TYPE 8099000 SIME MACK 3 514 T1R 8099010 SIME MACK 4 515 T3R 8099030 SIME MACK 5 515 T5...

Page 2: ...4...

Page 3: ...aulic systems 4 3 3 Electrical wiring 5 4 WORKING 6 4 1 Combustion adjustment 6 4 2 Nozzles recommended 6 4 3 Electrodes setting 7 4 4 Air damper adjustment 7 4 5 Pump pressure 7 4 6 Fuel heating 7 4...

Page 4: ...7A 2850 rpm 298 rad s Capacitor 4 F Ignition transformer Secondary 8 kV 16 mA Pump Pressure 7 15 bar Absorbed electrical power 0 165 kW 0 185 kW 0 8 0 0 4 Pressure in the combustion chamber mbar Light...

Page 5: ...ng gasket holes 5 Fix the ange 1 to the boiler door 4 using screws 2 and if necessary the nuts 3 interposing the insulating gasket 5 see g 3 Model A B C D E F G MACK 3 268 229 208 86 89 170 10 MACK 4...

Page 6: ...non return valve is required This solution however is less safe than previous one due to the possibility of leakage of the valve It is necessary to install a filter on the fuel supply line The standar...

Page 7: ...shut down of the burner by opening the ther mostats CONTROL BOX To remove the control box from the burner loosen screw A fig 8 and pull to the arrow direction after removing all components the 7 pin p...

Page 8: ...nd room temperature of 20 C BOILER BURNER Nozzle Pump pressure Burner output Air damper adjustment Code Model GPH Angle bar kg h 4 Set point Rond Estelle 3 8099000 MACK 3 0 55 60 S 12 2 1 3 7 Rond Est...

Page 9: ...recommended to proceed as follows Adjust the air damper as indicated in the table Mount the cover Check smoke number and CO2 Should it become necessary to modify the air output remove the cover by loo...

Page 10: ...s Clean the filter in the oil suction line and in the pump Clean the photoresistance see fig 9 page 5 Check for correct fuel consumption Replace the nozzle see fig 10 page 6 and check the correct posi...

Page 11: ...SOLUTION All led are off and the burner does not start Lack of electrical supply Check presence of voltage in the L1 N clamps of the 7 pin plug Check the conditions of the fuses Check that thermostat...

Page 12: ...Fonderie Sime S p A via Garbo 27 37045 Legnago Vr Italy Tel 39 0442 631111 Export Division fax number 39 0442 631293 Sime Service fax number 39 0442 631292...

Reviews: