67
EN
5.9
Expansion vessel
The expansion vessel installed on the Thermal unit has the fol-
lowing characteristics:
Description
U/M
DUETTO HE EV
25
35
Total capacity
l
10,0
Prefilling pressure
kPa
100
bar
1,0
Useful capacity
l
7,0
Maximum system content (*)
l
140
(*) Conditions of:
Average operating temperature 70°C (with high tempera-
ture system 80/60°C)
Start temperature at system filling 10°C.
m
CAUTION
– For systems with water content exceeding the max-
imum system content (as indicated in the table) an
additional expansion vessel must be prearranged.
– The difference in height between the relief valve
and the highest point of the system cannot exceed
6 metres. If the difference is greater than 6 metres,
increase the prefilling pressure of the expansion
vessel and the system when cold by 0.1 bar for each
meter increase.
5.10 Combustion chamber dimensions
The combustion chamber is a direct-passage type chamber and
conforms to the EN 303-3 standard Annex E. Its dimensions are
shown in the figure. An appropriate protective panel is applied
to the inner wall of the rear head on all models.
270
280
L
Fig. 22
Description
U/M
DUETTO HE EV
25
35
L
mm
305
405
Volume
dm
3
17,5
24,0
5.11 High-efficiency system pump
The high-efficiency pump is fitted with signalling LEDs (1), (2),
(3) and with the command button (4).
1
2
3
4
Fig. 23
1
Pump status signalling LED based on the colours shown in
the table below
LED colour
Status
Troubleshooting
Green
On
Normal operation
None
Off
No electrical power
Red/Green
Flashing
Anomaly in progress (*)
Red
Flashing
Anomaly in progress (*)
Red
On
Permanent safety shutdown
(*) For the details, consult the chapter “Possible faults and
NOTE:
In case of anomalies, the pump will stop and attempt to
restart; if the anomaly is resolved, the pump will restart auto-
matically. Otherwise, the pump will perform a permanent lock-
out.
2
LED indicating the selected regulation mode:
- constant number of rotations
- variable differential pressure (Δp-v)
- constant differential pressure (Δp-c)
3
LED indicating the selected characteristic curve: I, II, III
within the specific regulation mode
4
Command button for setting the pump. The button can only
be used by the installer or by authorised personnel:
- when pressed once or more, for roughly 1 s, it allows for se-
lecting the pump’s operating mode and the preferred char-
acteristic curve (for the details, consult the next paragraph)
- when pressed and held for 3s it automatically bleeds the
pump
- when pressed and held for 5s in unlocks the pump after pro-
longed periods of inactivity
- when pressed and held once for 8s it stops all actions that
can be executed through button (4). When pressed a second
time for 8s it activates the button’s functions again (4).