WARNINGS
– The smoke flue and the connection to the flue pipe
must be in compliance with the national and local
Standards and Legislation in force.
– The use of rigid ducts which are resistant to tem-
perature, condensate, mechanical stress and are
air-tight is compulsory.
– Outlet ducts which are not isolated are a risk of
danger.
2.11.1 Coaxial duct
Coaxial accessories
Description
Code
Ø 60/100
mm
Ø 80/125
mm
Coaxial duct kit
8084811
8084830
Extension W. 1000 mm
8096103
8096130
Extension W. 500 mm
8096102
-
Vertical extension W. 200 mm with
smoke analysis take-off point
8086908
-
Adapter for Ø 80/125 mm
-
8093120
Additional 90° curve
8095801
8095820
Additional 45° curve
8095900
8095920
Tile with joint
8091300
8091300
Roof outlet terminal W. 1284 mm
8091200
8091200
Vertical condensation recovery W. 200
mm
8092803
8092803
Load loss - Equivalent lengths
Model
Leq (linear metres)
Ø 60/100
mm
Ø 80/125
mm
90° curve
1
1
45° curve
0,5
0,8
Minimum-Maximum Lengths
Model
Duct Length Ø 60/100
Duct Length Ø 80/125
W Hori-
zontal (m)
H Vertical
(m)
W Hori-
zontal (m)
H Vertical
(m)
Min. Max. Min. Max. Min. Max. Min. Max.
Brava Slim
25 BF
-
3,5
1,3
(*)
5
3,5
6
4
7
Brava Slim
30 BF
-
3,0
1,3
(*)
5
3
6
4
7
m
CAUTION
(*) Vertical condensate recovery MUST be intro-
duced for vertical ducts (Type C32) or vertical sec-
tions of the duct (Type C42) longer than 1.3m.
Diaphragms for coaxial ducts
Boilers leave the factory equipped with a diaphragm (1) with
the following characteristics:
– Brava Slim 25 BF: diaphragm Ø 79 mm
– Brava Slim 30 BF: diaphragm Ø 81 mm.
1
Fig. 14
When the outlets are Type C12 or C42 the diaphragm is to be
removed or kept following the indications below:
Model
Diaphragm
for duct L
Brava Slim 25 BF
SI
(leave mounted)
< 1 m
Brava Slim 30 BF
Brava Slim 25 BF
NO
(remove it)
> 1 m
Brava Slim 30 BF
When the outlet isType C32 (vertically straight without any
curves), the presence of the diaphragm modifies the maxi-
mum length of the duct as shown below:
Model
Diaphragm
Max L (m)
Brava Slim 25 BF
SI
2,5
Brava Slim 25 BF
NO
5
Brava Slim 30 BF
SI
2,5
Brava Slim 30 BF
NO
5
2.11.2 Separate ducts (split pipe system Ø 80mm)
Constructing outlets for separate ducts indicates the use of
the "air-smoke split pipe system". This is to be ordered sep-
arately from the boiler and when connected to the other ac-
cessories, from those listed in the table below, completes the
smoke-outlet/ combustion air inlet assembly.
The total maximum length obtained from the length of the
outlet and inlet pipes is determined by the load loss of the in-
dividual accessories and must not be greater than 9 mm H
2
O
for Brava Slim 25 BF and 9.5 mm H
2
O Brava Slim 30 BF.
Separate accessories
Description
Code
Diameter Ø 80 (mm)
Air-smoke split pipe system (with
take-off point) + Diaphragm
8093020
90° curve M-F (6 pieces)
8077410
90° curve M-F (with take-off point)
8077407
90° curve M-F (insulated)
8077408
Extension W. 1000 mm (6 pieces)
8077309
Extension W. 1000 mm (insulated)
8077306
Extension W. 500 mm (6 pieces)
8077308
Extension W. 135 mm (with take-off
point)
8077304
Wall outlet terminal
8089501
Internal and external ring nut kit
8091500
Inlet terminal
8089500
45° curve M-F (6 pieces)
8077411
Condensate recovery W. 135 mm
8092800
Manifold
8091400
Tile with joint
8091300
Roof outlet terminal W. 1390 mm
8091201
Condensate recovery Tee
8093300
Inlet/outlet fitting Ø 80/125 mm
8091401