6

Programme for hot-water service 

(with storage capacity boiler unit)

Select the days that correspond with the heating phase. 

1= Monday, ... 7 = Sunday/8 = hot-water service programme

Start of phase 1: heating with fixed modality

End phase 1: heating with reduced modality

Start phase 2: heating with fixed modality

End phase 2: heating with reduced modality

Start phase 3: heating with fixed modality

End phase 3: heating with reduced modality

Copying of the daily programme

By pressing this key it is possible to repeat the current heating programme

for the 

next day

.

By pressing this key it is possible to repeat the current heating programme

for the 

previous day

.

As a confirmation the following day is displayed.

4

5

6

7

8

9

10

1 1

With the Logic Remote Control it is possible to manage the temperature of boiler unit on two

levels (a comfort level and one at reduced temperature) in accordance with the programme

chosen with parameter 62 (load hot-water service). To have access to the parameter press

the 

and

keys for at least 5 seconds and then go along the entered lines with the 

key until parameter 62 is reached. At this point four different programmes may be selected

with 

o

keys, with the following characteristics:

0

= 24 hours/ day - Hot water always available at the temperature set in parameter 3.

1

= standard - Hot water according to the daily heating programme. In the comfort periods

of  the  heating  the  temperature  of  the  boiler  unit  is  regulated  at  the  value  set  via  para-

meter 61.

2

= sservice suspended.

3

= second daily programme (8) - Everyday of the week  the temperature of the hot-water ser-

vice is set according to programme B. In this case the programming is one for all the days

of the week and three periods of time are available. In the periods of time set, the tem-

perature of the boiler unit is controlled via the temperature setting of parameter 61.

Start phase 1: preparation of the boiler unit to the comfort temperature

End phase 1: Temperature of boiler unit maintained at the reduced value

Start phase 2: Preparation of boiler unit to the comfort temperature

End phase 2:  Temperature of boiler unit maintained at the reduced value 

Start phase 3: preparation of boiler unit to the comfort temperature

End phase 3: Temperature of boiler unit maintained at the reduced value

5

6

7

8

9

10

Heating/hot-water 

service programme

With the heating programme it is possible to set the switching times of the temperature for a

period of a week. The weekly programme consists of 7 daily programmes. One daily program-

me allows 3 phases of heating. Each phase is defined by a starting time and a finishing time.

The n. 8 daily programme is for the hot-water service. If a phase is not required, the same star-

ting and finishing time may be entered.

Summary of Contents for Dewy HE WM

Page 1: ...GB Dewy HE WM User instructions PLEASE LEAVE THIS INSTRUCTION WITH THE USER ...

Page 2: ......

Page 3: ...nd the yellow domestic hot water led lights up at the same time When there is no request for hea ting or D H W production the leds and are off the tank unit maintenan ce temperature will appear on the red led scale 35 80 C The C H temperature can be adjusted by turning the knob of the C H potentio meter The set temperature is indi cated on the red led scale from 35 80 C and the yellow heating led ...

Page 4: ...leds are off call the local autho rised technical staff 2 system to avoid avoid frost damage GAS CONVERSION Should it be necessary to convert the appliance to a different gas from the one for which the boiler has been equipped approach the technical staff CLEANING AND MAINTENANCE Preventive maintenance and checking of the efficient operation of the equipment and safety devices must be carried out ...

Page 5: ... to the sum mer or winter position If the boiler lock out occurs again call local authorised Service Centre for technical assistance Other anomalies fig 6 When one of the red 40 80 C leds start flashing switch off the boiler and then try to ignite again After 2 or 3 unsuccessful attempts do not try again but call authorised techni cal staff SPIA ROSSA INTERMITTENTE Fig 5 SPIA ROSSA INTERMITTENTE L...

Page 6: ...l lowing list of items one after the other are displayed The thermo feeler continues to function independently of the display Day hour room temperature External temperature Hot water service temperature This data appear only if the relative feeler is connected or if they are transmitted by the regulator of the boiler Info key reference key grey colour The operating mode desired is selected by pres...

Page 7: ...e desired for hot water service at reduced level To have access to the reduced hot water service temperature parameter press the and keys at the same time for at least 5 seconds and then go along the entered lines with the key until parameter 61 is reached Regulate the value with and Before proceeding with the adjustment in the temperature on the regulator the thermosta tic valves which may be pre...

Page 8: ...rature set in parameter 3 1 standard Hot water according to the daily heating programme In the comfort periods of the heating the temperature of the boiler unit is regulated at the value set via para meter 61 2 sservice suspended 3 second daily programme 8 Everyday of the week the temperature of the hot water ser vice is set according to programme B In this case the programming is one for all the ...

Page 9: ...t days have elapsed the regulator will go on to the automatic function NOTE The vacation period may be cancelled by pressing a key of the operating mode Current values Display and setting of the gradient of the heating characteristics curve When the room temperature set is not reached choose the gradient indicated in point 2 11 3 Display of the current boiler temperature Display of the current pow...

Page 10: ...function Call an authorised Service Centre No communication between the Logica Remote Control and the boiler Call an authorised Service Centre 1 0 Error display Ignition lock out Rotate selector CR OFF EST INV RESET on the boiler control panel to the release position to reset operation fig 3 If the lock out re occurs call an authorised Service Centre Safety thermostat trip Rotate selector CR OFF E...

Page 11: ......

Page 12: ...nd Sime Ltd Unit D2 Enterprise Way Bradford Road Bradford West Yorkshire BD10 8EW Tel 0870 9911114 Fax 0870 9911115 www sime ltd uk e mail enquiries sime ltd uk Importer and distributor for Ireland Hevac Ltd Muirfield Drive Naas Road Dublin 12 Tel 01 4191919 Fax 01 4584806 e mail info hevac ie ...

Reviews: