Installation, use and maintenance manual
MANUAL CODE: 6328407
Page 45 / 148
Description
Unit
ECOMAXI 160 ErP
Compressor protection
Automatic-reset thermal circuit breaker
Fan
Centrifugal
Output mouth diameter
mm
160
Number of revs
RPM
1420
Nominal air flow rate
m
3
/h
350
Max. available head
Pa
100
Motor protection
Internal automatic-reset thermal circuit breaker
Capacitor
External covering, not in contact with water
Refrigerant
R134a
Load
g
900
Water storage
Nominal water storage capacity
l
160
Max. quantity of usable water Vmax(
3
)
l
230
Coil to connect to solar power system
m
2
Not included
Coil to connect to auxiliary heating source
m
2
Not included
Cathodic protection
Mg anode Ø26x400 mm
Insulation
50 mm high-density polyurethane foam
Defrosting
Passive air
Dimensions
mm
H. 1504 x D. 600 x
D
max.
650
Transport weight
kg
75
Indoor sound power Lw(A) (
4
)
dB(A)
59
Automatic anti-legionella sanitisation cycle (
5
)
YES
Max. operating pressure
Bar
7
(
1
) incoming air temperature 20°C (15°C max.), boiler storage ambient temperature 20°C, water heating from 10°C to
55°C, (in compliance with UNI EN 16147-2011)
(
2
) measurements as per UNI EN 12897-2006
(
3
) measurements as per UNI EN 16147-2011
(
4
) measurements as per EN 12102-2013
(
5
) automatic activation every 30 days of operation
Summary of Contents for ECOMAXI 160 ErP