7.1.3
BASIC MANAGEMENT
7.1.3.1
Manually turning the appliance on
and off
Press and hold the
button for 1 second.
The On/Stand-by LED will switch on/off.
The appliance can be switched on and off
even when operating according to specific
time settings. Please see parameters HOn and
HOF (section 7.1.3.6).
Manual on/off always has priority over pre-
set timed on/off settings.
If the keypad has been locked (section
7.1.3.3) or an advanced procedure is
running, the appliance cannot be
switched on/off as normal.
Every time the appliance is switched on, it
first runs a series of internal checks before
starting up the heat pump. This is shown by
a flashing light on the compressor
.
Once
the
checks
are
complete
(approximately 5 minutes), the light stays
on to show that the appliance is active.
7.1.3.2
Changing the operating mode
(AUTOMATIC, ECONOMY and
OVERBOOST)
7.1.3.2.1
AUTOMATIC mode
To manually start AUTOMATIC mode, do as follows:
Make sure that the keypad is not locked
(section 7.1.3.3) and that there are no
advanced procedures running;
Press the
button and hold for 1 second,
the flashing code “Auto” then appears;
Then press the
button again to confirm
and start AUTOMATIC mode.
To exit the procedure:
Press the
button to exit without changing
the operating mode.
7.1.3.2.2
ECO (economy) mode
To manually start ECO mode, do as follows:
Make sure that the keypad is not locked
(section 7.1.3.3), that there are no advanced
procedures running and that the appliance is
not in Overboost mode;
Press the
button and hold for 1 second,
the flashing code “ECO” then appears;
Then press the
button again to confirm
and start ECONOMY mode.
To exit the procedure:
Press the
button to exit without changing
the operating mode.
7.1.3.2.3
OVERBOOST mode
To manually start OVERBOOSTmode, do as follows:
Make sure that the keypad is not locked
(section 7.1.3.3) and that there are no other
advanced procedures running;
Press the
button and hold for 1 second,
the flashing code “Eco” or “Auto” then
appears;
Press the
or
buttons once or multiple
times until the flashing code “
ObSt
” appears
on the display;
Then press the
button again to confirm
and start OVERBOOST mode.
To exit the procedure:
Press the
button to exit without changing
the operating mode.
7.1.3.3
Locking/releasing the keypad
To lock the keypad, do as follows:
Ensure that there is no other advanced
procedure running;
Press and hold the
button and the
button for 1 second: “
Loc
” shows on the
display for 1 second.
If the keypad is locked, no operation can be
performed on the display interface.
If you press any button, “
Loc
” is shown on
the screen for 1 second.
To release the keypad:
Press and hold the
button and the
button for 1 second: “
UnL
” shows on the
display for 1 second.
7.1.3.4
Setting the temperature in ECO mode
(SP1)
Make sure that the keypad is not locked
(section 7.1.3.3) and that there are no other
advanced procedures running;
Press and release the
button: “
SP1
” shows
on the display;
Summary of Contents for ECOMAXI 160 ErP