7.1.3.12
Errors
Pr1
Upper boiler probe error
Solutions:
-
Check that the type of probe corresponds to
the setting under parameter P0;
-
Check that the probe is integral;
-
Check the connection between the appliance
and the probe;
-
Check the temperature of the upper part of
the boiler.
Main consequences:
-
The appliance stops working.
Pr2
Lower boiler probe error
Solutions:
-
As above only in relation to the probe for the
lower part of the boiler.
Main consequences:
-
The appliance stops working.
Pr3
Evaporator probe error
Solutions:
-
As above only in relation to the evaporator
probe.
-
The appliance stops working.
When the cause of the alarm disappears, the
appliance resumes normal operation.
7.1.3.13
Defrosting
Defrosting is activated:
Automatically,
when
the
evaporator
temperature falls below the temperature set
under parameter d17 (only if P4 is not 0);
In any case, between one defrosting cycle and
the next, the compressor must have been on for at
least d18 minutes. Otherwise, the defrosting
request is not accepted.
If P4 = 1, d2 is the evaporator temperature above
which defrosting stops. Vice versa, if P4 = 0 or P4 =
2, the parameter d2 is not considered.
If, when defrosting, the evaporator probe is above
the threshold set under parameter d2 and
parameter P4 = 1, the defrosting request is not
accepted.
Defrosting is made up of the following stages:
Defrosting phase: parameter d3 determines
the maximum duration of this phase.
Output statuses:
-
Compressor active where d1 = 1,
otherwise off;
-
Defrost relay active where d1 = 0 or d1 = 1,
otherwise off;
-
Fans on where d1 = 2, otherwise off.
Dripping phase: parameter d7 determines the
duration
of
this
phase.
Output statuses:
-
Compressor off;
-
Defrost relay active where d1 = 0 or d1 = 1,
otherwise off;
-
Fans off.
Drying phase: parameter d16 determines the
duration of this phase. Output statuses:
-
Compressor according to parameter d8;
-
Defrost relay active where d1 = 0 or d1 = 1,
otherwise off;
-
Fans on.
If the Anti-legionella function or the
Overboost function is in operation,
defrosting is not activated.
7.1.3.14
Setting the day and time
Make sure that the keypad is not locked
(section 7.1.3.3) and that there are no other
advanced procedures running;
Press and release the
button: the first
available code is shown on the display;
Press and release the
button or the
button until you see “
rtc
”;
The day is shown in the format 1-7 (1 =
Monday, etc.).