Description of parameter
Abbre
viation
Unit
Min.
Max.
Default Notes
be changed, it can only
be viewed
Delay from appliance on
C0
min
0
240
5
Compressor protective
devices
Delay from last ON
C1
min
0
240
5
Delay from last OFF
C2
min
0
240
5
Minimum time ON
C3
sec
0
240
0
Number of compressor operating hours
for maintenance request
C10
h
0
9999
0
0 = function excluded
Air temperature reading delay for cold
evaporator test
C11
min
0
999
120
Minimum delay between fan ON and
compressor
activation
to
check
incoming air temperature
C12
min
0
240
1
Timeout for solar thermal cycle
C13
min
0
240
20
Delay for faulty fan check
C14
min
-1
240
20
-1 = function disabled
Type of defrosting
d1
----
0
2
2
0 = with resistors
1 = hot gas
2 = compressor stop
Evaporator temperature for defrosting
stop (only where P4 = 1)
d2
°C/°F
-50.0
50.0
3.0
Maximum defrosting duration
d3
min
0
99
20
Threshold for automatic defrosting start
(evaporator temperature)
d17
°C/°F
-50.0
50.0
-2.0
Minimum compressor ON time for
defrosting start
d18
min
0
240
60
Minimum alarm probe (only AL1
notification)
A0
----
0
2
0
0 = upper probe
1 = lower probe
2 = evaporator probe
Minimum alarm setpoint (only AL1
notification)
A1
°C/°F
0.0
50.0
10.0
Minimum alarm delay type (only AL1
notification)
A2
----
0
1
0
0 = Disabled
1 = Absolute
Maximum alarm probe (only AH
notification)
A3
----
0
2
0
0 = upper probe
1 = lower probe
2 = evaporator probe
Maximum alarm setpoint (only AH
notification)
A4
°C/°F
0.0
199.0
90.0
Maximum alarm delay type (only AH
notification)
A5
----
0
1
0
0 = Disabled
1 = Absolute
AL1
minimum
alarm
delay
from
appliance on (notification only)
A6
min
0
240
120
AL1 and AH temperature alarm delay
(only notification)
A7
min
0
240
15
Alarm differential
A11
min
0.1
30.0
2.0