Installation, use and maintenance manual
MANUAL CODE: 6328407
Page 69 / 148
8
MAINTENANCE AND CLEANING
WARNING: any repairs to the appliance
must be carried out by qualified
technicians. Incorrect repairs may put
the user at serious risk. If your
appliance needs any kind of repair,
please contact the support service.
WARNING: before performing any
maintenance work, ensure that the
appliance is not connected to the
electric power supply and that there is
no risk of this accidentally happening.
For all maintenance and cleaning,
please disconnect the electric power
supply.
8.1
Resetting safety devices
The appliance is equipped with a safety
thermostat. This manual-reset device is tripped by
overtemperatures.
To reset the protective device:
Disconnect the appliance from the electric
power supply;
Remove any air ducts (see section 5.2);
Remove the top cover, first unscrewing the
screws holding it in place (Fig. 17);
Manually reset the safety thermostat from
above (Fig. 18). If the device is tripped, the
central pin on the thermostat protrudes by
approximately 4 mm. The button is protected
by a metal plate to the side of the display.
Refit the top cover.
Fig. 17 – Removing the top cover
Fig. 18 - Resetting the safety thermostat
WARNING: the safety thermostat may
be triggered by a fault in the control
board or by a lack of water in the tank.
WARNING: Repairing parts present for
safety reasons compromises safe
operation of the appliance. Only
replace defective parts with original
spares.
NOTE: if the thermostat is triggered, the
electrical resistor is excluded, but the
heat pump can still orun perate within
the permitted operating limits.
Click