1.7.2 Burners assembly
The boiler door details is shown in figure
3/a for burner mounting.
The burners must be regulated such that
the CO
2
value is that indicated in point 1.3,
with a tolerance of ± 5%.
1.8
CONNECTION OF
CONDENSATION
WATER TRAP (fig. 4)
The drip board and its water trap must be
connected to a civil drain through a pipe (ø
25) with a slope of at least 5 mm per metre
to ensure drainage of condensation water.
The plastic pipes normally used for civil
drains are the only type of pipe which is
appropriate for conveying condensation
to the building’s sewer pipes.
R 75
ø 110
M8
Fig. 3/a
37
1
2
Fig. 4
KEY
1 Drain hose
2 Condensate drain tap