17
C12
C32
C42
2
7
6
4
1
2
min. 4 m - max 6 m
"25"/
7 m
"30"
8
x
y
x + y = min. 3,6 m/max 6 m
"25"
x + y = min. 3,6 m/max 7 m
"30"
5
5
3 8
2
1
1
min. 3,6 m - max 6 m
"25"/
7 m
"30"
Fig. 17
IMPORTANT:
– Each additional 90° curve installed reduces the available length by 1 metre.
– Each additional 45° curve installed reduces the available length by 0.50 metres.
– The insertion of the recovery condenses (8) is obligatory in the tipologia of C32 download.
– The insertion of the recovery condenses (8) is obligatory in the tipologia of C42 download
when the section “y” is advanced to 2,5 metres.
KEY
1
Coaxial flue kit code 8084830
2
Extension L. 1000 code 8096130
3
Vertical extension L. 200 ø 60/100 code 8086908
4 a Additional 90° curve code 8095820
4 a Additional 45° curve code 8095920
5
Adapter from ø 80/125 code 8093120
6
Articulated tile code 8091300
7
Roof outlet terminal L. 1284 code 8091200
8
Vertical condensation collector L. 200 ø 60/100 cód. 8092803