Programme for hot-water service
with storage capacity boiler unit
Select the days that correspond with the heating phase.
1= Monday, ... 7 = Sunday/8 = hot-water service programme
Start of phase 1: heating with fixed modality
End phase 1: heating with reduced modality
Start phase 2: heating with fixed modality
End phase 2: heating with reduced modality
Start phase 3: heating with fixed modality
End phase 3: heating with reduced modality
Copying of the daily programme
By pressing this key it is possible to repeat the current heating programme
for the
next day
.
By pressing this key it is possible to repeat the current heating programme
for the
previous day
.
As a confirmation the following day is displayed.
4
5
6
7
8
9
10
1 1
With the Logic Remote Control it is possible to manage the temperature of boiler unit on two
levels (a comfort level and one at reduced temperature) in accordance with the programme
chosen with parameter 62 (load hot-water service). To have access to the parameter press
the
and
keys for at least 5 seconds and then go along the entered lines with the
key until parameter 62 is reached. At this point four different programmes may be selected
with
o
keys, with the following characteristics:
0
= 24 hours/ day - Hot water always available at the temperature set in parameter 3.
1
= standard - Hot water according to the daily heating programme. In the comfort periods
of the heating the temperature of the boiler unit is regulated at the value set via para-
meter 61.
2
= sservice suspended.
3
= second daily programme (8) - Everyday of the week the temperature of the hot-water ser-
vice is set according to programme B. In this case the programming is one for all the days
of the week and three periods of time are available. In the periods of time set, the tem-
perature of the boiler unit is controlled via the temperature setting of parameter 61.
Start phase 1: preparation of the boiler unit to the comfort temperature
End phase 1: Temperature of boiler unit maintained at the reduced value
Start phase 2: Preparation of boiler unit to the comfort temperature
End phase 2: Temperature of boiler unit maintained at the reduced value
Start phase 3: preparation of boiler unit to the comfort temperature
End phase 3: Temperature of boiler unit maintained at the reduced value
5
6
7
8
9
10
–
Heating/hot-water
service programme
With the heating programme it is possible to set the switching times of the temperature for a
period of a week. The weekly programme consists of 7 daily programmes. One daily program-
me allows 3 phases of heating. Each phase is defined by a starting time and a finishing time.
The n. 8 daily programme is for the hot-water service. If a phase is not required, the same star-
ting and finishing time may be entered.