background image

SYMPTOM

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

Motor will not run

Disconnect switch is off

Be sure switch is on.

Fuse is blown or circuit breaker tripped

Replace fuse or reset circuit breaker.

Starting switch is defective

DISCONNECT POWER; Replace starting switch.

Wires at motor are loose, 

Refer to instructions on wiring (Page 7). DISCONNECT POWER; check and

disconnected, or wired incorrectly 

tighten all wiring. 

Capacitor voltage may be hazardous. To discharge 

capacitor, hold insulated handle screwdriver BY THE HANDLE and 
short capacitor terminals together. Do not touch metal screwdriver 
blade or capacitor terminals. If in doubt, consult a qualified electrician.

Pressure switch contacts are dirty

DISCONNECT POWER and file contacts with emery board or nail file.

Motor runs hot and 

Motor is wired incorrectly

Refer to instructions on wiring.

overload kicks off

Voltage is too low

Check with power company. Install heavier wiring if wire size is too small  
(See Electrical / Wiring Chart).

Pump cycles too frequently

See section below on too frequent cycling.

Motor runs but no 

Pump in new installation did 

In new installation:

water is delivered*

not pick up prime through: 

1. Improper priming 

1. Re-prime according to instructions.

2. Air leaks

2. Check all connections on suction line, AVC, and ejector with

soapy water or shaving cream.

3. Leaking foot valve or check valve

3. Replace foot valve or check valve.

Pump has lost prime through:

In installation already in use:

1. Air leaks

1. Check all connections on suction line and shaft seal.

2. Water level below suction pipe inlet

2. Lower suction line into water and re-prime. If receding water level 

in well exceeds 25’ (7.6M), a deep well pump is needed.

Foot valve or strainer is plugged

Clean foot valve or strainer.

Ejector or impeller is plugged

Clean ejector or impeller.

Check valve or foot valve is stuck shut 

Replace check valve or foot valve.

Pipes are frozen

Thaw pipes. Bury pipes below frost line. Heat pit or pump house.

Foot valve and/or strainer are 

Raise foot valve and/or strainer above bottom of water source.

buried in sand or mud

Clean foot valve and strainer.

Water level is too low for shallow well  

A deep well jet package may be needed (over 25 ft. to water) 

setup to deliver water

to deliver water.

Pump does not 

Water level in well is lower than 

A deep well jet will be needed if your well is more than 25’ (7.6M)

deliver water to full 

estimated

depth to water.

capacity

Steel piping (if used) is corroded or 

Replace with plastic pipe where possible, otherwise with new steel pipe.

limed, causing excess friction
Piping is too small in size

Use larger piping.

Packed well point

Backflush well point or sink new point.

Pump delivers water but

Pressure switch is out of adjustment or

DISCONNECT POWER; adjust or replace pressure switch.

does not shut off or

contacts are welded together

pump cycles too

Faucets have been left open

Close faucets.

frequently

Venturi, nozzle or impeller is clogged

Clean venturi, nozzle or impeller.

Standard pressure tank is waterlogged

Drain tank to air volume control port. Check AVC for defects. Check 

and has no air cushion

all connections for air leaks.

Pipes leak

Check connections.

Foot valve leaks

Replace foot valve.

Air charge too low in pre-charged tank

DISCONNECT POWER and open faucets until all pressure is relieved.
Using tire pressure gauge, check air pressure in tank at valve stem 
located on the tank. If less than pressure switch cut-in setting (30-50 
PSI), pump air into tank from outside source until air pressure is 2 PSI 
less than cut-in setting of switch. Check air valve for leaks (use soapy
solution) and replace core if necessary.

Air spurts from faucets

Pump is picking up prime

When pump has picked up prime, it should pump solid water with no air.

Leak in suction side of pump

Suction pipe is sucking air. Check joints for leaks with soapy water.

Well is gaseous

Consult factory about installing a sleeve in the well

Intermittent over-pumping of well.

Lower foot valve if possible, otherwise restrict pump discharge

(Water drawn down below foot valve.)

Troubleshooting

12

* (Note: 

Stop pump;

then check prime
before looking for
other causes.
Unscrew priming
plug and see if water
is in priming hole).

For parts or assistance, call Simer Customer Service at 

1-800-468-7867 / 1-800-546-7867

Summary of Contents for 2806E-02

Page 1: ...67 Fax 1 800 390 5351 Web Site http www simerpump com Installation Operation Parts For further operating installation or maintenance assistance Call 1 800 468 7867 English Pages 2 12 Installation Fonc...

Page 2: ...pump Periodically inspect pump and system components Wear safety glasses at all times when working on pumps Keep work area clean uncluttered and properly lighted store properly all unused tools and e...

Page 3: ...nstallation operation maintenance or storage nor to other than normal application use or service including but not limited to operational failures caused by corrosion rust or other foreign materials i...

Page 4: ...on 1 1 1 4 1 1 2 Up to 25 Ft 25 to 100 Ft 100 to 600 Ft Tank Tank is pre charged with 40 pounds per square inch PSI air pressure at the factory Your tank requires an air charge of 28 PSI for proper op...

Page 5: ...pump include a check valve see Figure 1 Support the pipe so that there are no dips or sags in the pipe so it doesn t strain the pump body and so that it slopes slightly upward from the well to the pu...

Page 6: ...The suction pipe should be at least as large as the suction port on the pump Use teflon tape or a teflon based pipe joint compound on threaded pipe joints Support the pipe so that there are no dips o...

Page 7: ...in the pump will not harm it if it freezes Discharge Pipe and Pressure Tank Connections 7 For parts or assistance call Simer Customer Service at 1 800 468 7867 1 800 546 7867 Sealing Pipe Joints Use o...

Page 8: ...in the switch to the green ground screw under the motor end cover Use a solid copper wire at least as large as the power sup ply wires 3 Connect the ground wire to a grounded lead in a ser vice panel...

Page 9: ...ll plugs Refill the pump and piping You may have to repeat this several times in order to get all the trapped air out of the piping A pump lifting water 25 may take as long as 15 minutes to prime 4 Af...

Page 10: ...es Water slinger seal plate gasket shaft seal and diffuser gasket Includes Pump body nozzle and venturi Includes Seal and Gasket Kit impeller and diffuser Key Part 2805E 02 No Description 1 2HP 1 Moto...

Page 11: ...er 1 U31 380P 2 Air Valve and Cap 1 U212 160 3 Replacement Tank 1 HT7 01 4 Inlet Flange 1 U31 442P 5 Nut 5 16 18 Hex 6 U36 202BT 6 Elbow 3 4 MPT x 1 Insert 1 U78 770P 7 Clamp 2 U19 55SS 8 Hose 1 x 29...

Page 12: ...ttom of water source buried in sand or mud Clean foot valve and strainer Water level is too low for shallow well A deep well jet package may be needed over 25 ft to water setup to deliver water to del...

Page 13: ...t me Toujours porter des lunettes de s curit pour intervenir sur la pompe et les composants du syst me Garder la zone de travail propre non encombr e et bien clair e tous les outils et tout l quipemen...

Page 14: ...qui n ont pas t utilis s ou entretenus normalement y compris mais sans s y limiter aux produits ayant des pannes de fonctionnement caus es par la corrosion la rouille ou autre corps tranger dans le s...

Page 15: ...servoir requiert une charge d air de 28 lb po2 pour fonctionner correctement V rifier la pression du r servoir l aide d un manom tre pour pneus et r gler la charge d air La pr charge du r servoir doit...

Page 16: ...de fa on qu il ne fl chisse pas et qu il n exerce pas de contrainte sur le corps de la pompe L incliner aussi l g rement en montant vers la pompe les points hauts risquent de causer des poches d air l...

Page 17: ...cords filet s au t flon sur les raccords filet s Supporter le tuyau de fa on qu il ne fl chisse pas et qu il n exerce pas de contrainte sur le corps de la pompe De plus il doit tre l g rement inclin e...

Page 18: ...u n endommagera pas la pompe en cas de gel Tuyau de refoulement et connexions du r servoir sous pression 18 Pour les services des pi ces ou d assistance appeler le service la client le Simer en compos...

Page 19: ...la terre qui se trouve sous le couvercle d extr mit du moteur Utiliser un fil de cuivre massif dont le diam tre sera au moins aussi gros que les fils de l alimentation lectrique 3 Connecter le fil de...

Page 20: ...l faudra peut tre r p ter cette op ration plusieurs fois jusqu ce que tout l air emprisonn dans les tuyaux soit chass Si la pompe aspire l eau d une hauteur de 7 60 m tres 25 pieds il lui faudra peut...

Page 21: ...tanch it impulseur et diffuseur 2805E 02 R f D signation des pi ces 1 2 CV 1 Moteur J218 577PKG 2 Plaque d tanch it N3 9 3 Trousse de joints d tanch it FPP1550 P2 4 Corps de la pompe N176 38 5 Trousse...

Page 22: ...31 380P 2 Valve d air et bouchon 1 U212 160 3 R servoir de rechange 1 HT7 01 4 Bride d admission 1 U31 442P 5 crou six pans de 5 16 18 6 U36 202BT 6 Coude de 3 4 de po MPT x garniture de 1 po 1 U78 77...

Page 23: ...air dans le r servoir soit de 2 lb po2 inf rieures au r glage de d clenchement du pressostat S assurer que la valve ne fuit pas utiliser une solution savonneuse pour cela Au besoin remplacer l obus d...

Page 24: ...El rea de trabajo se debe mantener limpia ordenada y con iluminaci n adecuada guarde las herramientas y el equipo que no utilice en un lugar apropiado Mantenga a los visitantes a una distancia segura...

Page 25: ...ntenimiento o almacenaje incorrectos ni a ninguna otra cosa que no sea su aplicaci n uso o servicio normales incluyendo pero no limitado a fallas operacionales causadas por corrosi n oxidaci n u otros...

Page 26: ...a carga de aire de 28 PSI para un fun cionamiento correcto verifique la presi n del tanque con un man metro para neum ticos y ajuste la carga de aire seg n sea necesario Es importante chequear la pre...

Page 27: ...a de manera que no tenga incli naciones ni combaduras para no ejercer presi n sobre el cuerpo de la bomba y hacer que se incline ligeramente hacia arriba desde el pozo a la bomba los puntos elevados p...

Page 28: ...menos del mismo tama o que la toma de aspiraci n en la bomba Utilice cinta de tefl n o un compuesto a base de tefl n en las juntas fileteadas de la tuber a Apoye la tuber a de manera que no tenga incl...

Page 29: ...e congela Tuber a de Descarga y Conexiones del Tanque de Presi n 29 Para repuestos o asistencia llame al Servicio al Cliente de Simer 1 800 468 7867 1 800 546 7867 Sellado de las Juntas de Tuber a Use...

Page 30: ...lo menos del tama o de los hilos de suministro de energ a 3 Conecte el hilo de toma de tierra a un conductor a tierra del tablero de servicio a un tubo met lico de agua subterr nea a un entubamiento m...

Page 31: ...para sacar todo el aire atrapado dentro de la tuber a La cebadura de una bomba que deba extraer agua a una altura de 25 pies puede demorar hasta 15 minutos 4 Despu s de que la bomba haya acumulado pre...

Page 32: ...usor Incluye Cuerpo de la bomba boquilla y venturi Incluye Juego de junta y empaquetadura impulsor y difusor Clave 2805E 02 No Descripci n de la pieza 1 2HP 1 Motor J218 577PKG 2 Unidad de la placa de...

Page 33: ...80P 2 V lvula de aire y casquete 1 U212 160 3 Tanque de repuesto 1 HT7 01 4 Brida de admisi n 1 U31 442P 5 Tuerca hexagonal de 5 16 18 6 U36 202BT 6 Codo de inserci n de 3 4 MPT x 1 1 U78 770P 7 Abraz...

Page 34: ...resi n del aire sea 2 PSI menos que la presi n de activaci n del man stato Verifique que no haya fugas en la v lvula de aire utilice una soluci n jabonosa y reemplace el n cleo si es necesario El nive...

Page 35: ...35...

Page 36: ......