User manual - COUNTER SLB-94
Functions of buttons when editing numeric and switching parameters:
While editing numeric parameter:
change of current (flashing) digit
slide change of value (acceleration, deceleration, direction change)
While editing switch parameter - selection of switch parameter.
If numerical parameter is being edited, a short press of
[ENTER]
button
change edited position. A long press of
[ENTER]
button (at lest 2 sec.)
causes of display a
SEt?
ask, which allow user to make sure if change of
the parameter value is correct. If switch parameter is being edited, a short
press of
[ENTER]
button causes of display a
SEt?
ask. When
[ENTER]
button is pressed again (while
SEt?
is displayed) the new value of the
parameter is stored in EEPROM memory.
Pressing this button operator can cancel the changes done up to now (if they
were not approved by
[ENTER]
button after the
SEt?
ask) and come back
to menu
7.3.
MENU DESC
RIPTION
Cd 0 - - -
Password checking. If password is set different from
0000
, than every enter to
main menu follows the entering of password. If entered password is correct first
menu position else warning
Error
will be displayed, and unit returns to
measurement mode.
Due to problem with direct displaying of
m
letter, it is exchanged with special sign
. Independently in user manual letter
m
is used to make it more readable
(example:
modE
).
7.3.1.
rELAy1
÷
“rELAy4” menu
This menu allows to configure the operation mode of relays and LEDs marked
R
(e.g.
R1
). If there are few relay outputs available, then every output has its own configuration
menu (e.g. menu
rELAy2
for relay (LED)
R2
). Principle of the relays operation is described
in paragraph
CONTROL OF THE RELAY OUTPUTS
.
Src3
,
Src4
- these parameters are available in
rELAy3
,
rELAy4
menus only, and
allow selection of counter for driving of the relay. Relays R3 and R4 are fully
configurable in all operation modes of the counter. User can select the counter
due to which value the relay will be driven. Possibilities:
main
- control of the relay due to value of main counter
CyCLES
- control of the relay due to value of cycle counter
SEtP 1
÷
SEtP 4
- threshold of the relay (range -99999 ÷ 999999). Negative values can be
input by selecting a - sign on first digit (to change value use
[^]
and
[v]
buttons).
25
MENU
ESC
ENTER
i