User manual - COUNTER SLB-94
7.3.4.
“rESEtS” menu
This menu contains parameters defining the resets modes of all counters.
rES m
- defines enabled sources of
main counter
zeroing. Available options:
”mAn”
- manual reset only. This value enables only manual reset, which can be done
by pressing the [
RESET
] button on the front panel. This operation must to be
approved by [
ENTER
] button.
”EL”
- it enables the clearing of the counter by external electrical signal, feeded to
input
{ B }
. When an active state is delivered to this input, the clearing of the
counter happens. The active state must be longer than 1 ms. In this mode
manual clearing of the counter is unavailable.
”ALL”
- this option enables both manual (using
[RESET]
button) and electronic reset.
”nonE”
- this option disables both manual and electronic reset.
Zeroing of the totalizer can be done via RS-485 interface by presets of some
registers with value 0000h. Remote zeroing is available in
ALL
,
EL
and
mAn
modes too.
ArES m
- this parameter enables the auto zeroing mode (
AUTORESET
function).
AUTORESET
clears
main counter
when it reaches the value equal to
SEtP 1
.
This parameter can be set to:
“on”
-
AUTORESET
function is active,
“oFF”
-
AUTORESET
function is inactive.
rES c
- defines enabled sources of
cycles counter
zeroing. Available options:
”mAn”
- manual reset only. This value enables only manual reset, which can be done
by pressing the [
RESET
] button on the front panel. This operation must to be
approved by [
ENTER
] button.
”EL”
- it enables the clearing of the counter by external electrical signal, feeded to
input
{ C }
. When an active state is delivered to this input, the clearing of the
counter happens. The active state must be longer than 1 ms. In this mode
manual clearing of the counter is unavailable.
”ALL”
- this option enables both manual (using
[RESET]
button) and electronic reset.
”nonE”
- this option disables both manual and electronic reset.
Zeroing of the totalizer can be done via RS-485 interface by presets of some
registers with value 0000h. Remote zeroing is available in
ALL
,
EL
and
mAn
modes too.