User manual - COUNTER SLB-94
Power consumption
max. 4,5 VA @ 85 ÷ 260V AC/DC
max. 4,5 VA @ 16V ÷ 35V AC
max. 4,5 W @ 19V ÷ 50V DC
Pulse inputs
A input
B input
C input
D input
COM
counting input (terminal no. 16)
main counter reset input (terminal no. 17)
cycles counter reset input (terminal no. 18)
totalizer reset input (terminal no. 19)
common terminal (terminal no. 20)
Input levels
low level:
high level:
0V ÷ 1V
10V ÷ 30V (about 12 mA @ 24V)
Max. input frequency
electronic: 10 kHz
contact: 90 Hz (adjustable filter)
Outputs
relay:
or OC-type:
sensor power supply:
4 NO, 1A/250V AC (cos
ϕ
= 1)
4 30mA / 30VDC / 100mW
24V +5%, -10% / max. 100 mA, stabilized
Measurement range
main counter:
cycles counter:
totalizer counter:
-99 999 ÷ 999 999, plus decimal point
0 ÷ 999 999, plus decimal point
-99 999 999 999 ÷ 999 999 999 999
Communication interface
RS 485, 8N1 and 8N2, Modbus RTU,
not separated
Baud rate
1200 bit/s ÷ 115200 bit/s
Display
LED, 6 digit, 13mm height, red
Data memory
non-volatile memory, EEPROM type
Protection level
IP 65 (from front, after using waterproof cover)
IP 40 (from front)
IP 20 (housing and connection clips)
Housing type
Housing material
Housing dimensions
Panel cutout
Assembly depth
Panel thickness
panel
NORYL - GFN2S E1
96 x 48 x 100 mm
90,5 x 43 mm
102 mm
max. 5 mm
Operating temperature
(depending on version)
0°C to +50°C
or -20°C to +50°C
Storage temperature
(depending on version)
-10°C to +70°C
or -20°C to +70°C
Humidity
Altitude
5 to 90% no condensation
up to 2000 meters above sea level
Screws tightening max. torque
0,5 Nm
Max. connection leads diameter
2,5 mm
2
5
Summary of Contents for SLB-94
Page 47: ...User manual COUNTER SLB 94 47...