background image

User manual for time counter SLC-457

4. 

   DEVICE INSTALLATION

  

The unit has been designed and manufactured in a way assuring a high level of user

safety and resistance to interference occurring in a typical industrial environment. In order to

take full advantage of these characteristics installation of the unit must be conducted correctly

and according to the local regulations.

- Read the basic safety requirements on page 3 prior to starting the installation.

-  Ensure that the power supply network voltage corresponds to the nominal

voltage stated on the unit’s identification label.

- The load must correspond to the requirements listed in the technical data.

- All installation works must be conducted with a disconnected power supply.

- Protecting the power supply clamps against unauthorized persons must be

taken into consideration.

4.1. 

  

UNPACKING

  

After removing the unit from the protective packaging, check for transportation damage.

Any transportation damage must be immediately reported to the carrier. Also, write down the

unit serial number on the housing and report the damage to the manufacturer.

Attached with the unit please find:

- warranty,
- user’s manual for 

SLC-457 

unit (device)

4.2. 

  

CONNECTION METHOD

  

Caution

- Installation should be conducted by qualified personnel . During installation all

available safety requirements should be considered. The fitter is responsible for

executing the installation according to this manual, local safety and EMC

regulations.

- The unit is not equipped with an internal fuse or power supply circuit breaker.

Because of this an external time-delay cut-out fuse with minimal possible nominal

current value must be used (recommended bipolar, max. 2A) and a power supply

circuit-breaker located near the unit. In the case of using a monopolar fuse it must

be mounted on the phase cable (L).

- The power supply network cable diameter must be selected in such a way that in

the case of a short circuit of the cable from the side of the unit the cable shall be

protected against destruction with an electrical installation fuse. 

- Wiring must meet appropriate standards and local regulations and laws.

 

- In order to secure against accidental short circuit the connection cables must be

terminated with appropriate insulated cable tips. 

6

Summary of Contents for SLC-457

Page 1: ...L for time counter type SLC 457 firmware version 1 01 or higher Read the user s manual carefully before starting to use the unit Producer reserves the right to implement changes without prior notice 1...

Page 2: ...4 bri parameter 14 7 3 5 Scod parameter 15 7 4 MENU STRUCTURE 15 8 THE MODBUS PROTOCOL HANDLING 16 8 1 LIST OF REGISTERS 16 8 2 TRANSMISSION ERRORS DESCRIPTION 17 8 3 EXAMPLES OF QUERY ANSWER FRAMES...

Page 3: ...troubleshooting in the case of malfunction Neighbouring and mating equipment must meet the requirements of appropriate standards and regulations concerning safety and be equipped with adequate anti o...

Page 4: ...an be changed from 1200 to 115200 baud SLC 457 has additional sensor supply output non separated stabilized 24V DC 5 max 100 mA 3 TECHNICAL DATA Power supply voltage depending on version External fuse...

Page 5: ...orque 0 5 Nm Max connection leads diameter 2 5 mm2 Safety requirements according to PN EN 61010 1 1999 PN EN 61010 1 A2 1999 installation category II pollution degree 2 voltage in relation to ground 3...

Page 6: ...t serial number on the housing and report the damage to the manufacturer Attached with the unit please find warranty user s manual for SLC 457 unit device 4 2 CONNECTION METHOD Caution Installation sh...

Page 7: ...the unit must be applied To avoid the unit of improper indications keep recommendations listed below Avoid common parallel leading of signal cables and transmission cables together with power supply c...

Page 8: ...evel RESET counter clearing rising logical edge COM common terminal All connections must be made while power supply is disconnected Depend on version 85 230 260V AC DC or 19 24 50V DC 16 24 35V AC Fig...

Page 9: ...nit is operating Excessively high temperatures cause faster ageing of the internal components and shorten the fault free time of unit operation In cases where the unit gets dirty do not clean with sol...

Page 10: ...RINCIPLE OF OPERATION After turning the power supply on device ID and software version are showed on the display next the controller goes to the counting mode After that unit goes to counting mode res...

Page 11: ...requirements it is redcommended to use IR remote controller for menu settings configuration IR remote controller is available optionally as additional equipement The device menu allow user to set all...

Page 12: ...exits the menu mode and returns to the counting mode only if no parameters are in editing mode 7 2 PARAMETERS EDITION To start edition of any parameter user should select name of desired one using v b...

Page 13: ...of password If entered password is correct first menu position will be displayed else warning Err and unit returns to counting mode Due to problem with direct displaying of m letter it is exchanged wi...

Page 14: ...via RS 485 interface This additional delay allows the device to work with poor RS converters which do not works properly on baud rates higher than 19200 This parameter can be set to one of values Std...

Page 15: ...password the access to the menu is possible by the one use password To get this password please contact witch Marketing Division Please set new user password immediately after use of the one use passw...

Page 16: ...minutes Range from 0 to 100 hours 60000 minutes Write of any value to this register clears counter 02h Yes Counter value hours minutes decimally Value of this register equals hours 100 minutes e g 310...

Page 17: ...decimal Field description ADDR Device address on modbus network FUNC Function code REG H L Starting address address of first register to read write Hi and Lo byte COUNT H L No of registers to read wri...

Page 18: ...C BYTE C DATA H L CRC L H 01 03 02 04 D2 3A D9 DATA H L 04D2h 1234 counter value 12 34 12 hours 34 minutes 4 Try to write improper value to register 22h baud rate ADDR FUNC REG H L DATA H L CRC L H 01...

Page 19: ...er s value Desc page rinP Activation of RESET input oFF 13 RS 485 interface configuration rS menu Addr Device address 0 13 bAud Baud rate 9 6 14 mbAc Blocking of access to the configuration registers...

Page 20: ...SIMEX SIMEX Sp z o o ul Wielopole 7 PL 80 556 Gda sk Poland tel 48 58 762 07 77 fax 48 58 762 07 70 http www simex com pl e mail info simex com pl...

Reviews: