Installation Instructions Document No. 466-1574
.
24
Figure 4. Wire Hardwire Sensors Normally Closed
Connecting the Universal/Garage
Door Opener Module*
Use the following to connect a universal module to be
used to open a garage door:
1. Set the unit code of the universal module to a
unique unit number between 1 and 8.
2. Set the house code to the house code for the
installation.
3. Set the module’s switches to momentary and
relay only.
4. Connect the terminals on the universal mod-
ule to the button terminals on the garage door
opener.
5. Plug the universal module into a wall outlet.
Note: See the “Programming Light and Appliance Con-
trols*” on page 26 to program a KeyChain Touchpad to
open a garage door.
Connecting the Power Transformer
Connect the power transformer as shown in Figure 5.
Plug the transformer into an unswitched outlet
Note: Failure to terminate unused inputs as shown will
cause the Control Panel to indicate module 1 and mod-
ule 2 failure.
Figure 5. Power Transformer Control Panel Con-
nections
Connecting the Backup Batteries
Installing a Non-rechargeable Battery
Connect a 9-Volt lithium battery (ITI #34-037) to the
battery strap as shown in Figure 6.
Figure 6. Control Panel Battery Installation
Note: The Control Panel will initially indicate a low battery
by lighting the SYSTEM STATUS button. If this button is
pressed the Control Panel will announce, System low bat-
tery.
The Control Panel does a battery test every 4 hours
and will clear the status message if the battery is good.
Perform a sensor test, “Testing Sensors” on page 30,
to perform an immediate battery test.
8988G22B.DS4
All inputs are Class II
power-limited circuits.
Hardwire
Input 1
or
Exterior
Siren
–
HARDWIRE INPUTS/SIREN
Hardwire
and
Power
Common
+
Hardwire
Input 2
or
Interior
Siren
–
Normally
Closed
47k
Normally
Closed
8988G03B.DS4
CLASS II POWER
TRANSFORMER
PART NO. 22-091
All inputs are Class II
power-limited circuits.
AC POWER
Hardwire
Input 1
or
Exterior
Siren
–
HARDWIRE INPUTS/SIREN
Hardwire
and
Power
Common
+
Hardwire
Input 2
or
Interior
Siren
–
9 VAC
8 9 5 9 G 1 7 D . D S F
9 V O L T B A T T E R Y
* = Not Available with Basic Model