Installation Instructions Document No. 466-1574
35
To test communication with the central station:
1. Call the central station and tell the operator that
you will be testing the system.
2. Arm the system.
3. Test each of the wireless panic buttons and trip at
least one sensor of each type—fire, intrusion,
etc.—to verify that the appropriate alarms are
working correctly.
4. When you finish testing the system, call the cen-
tral station to verify that the alarms were
received.
Testing the X-10 Lamp Modules*
Use Table 6 on page 9 to determine the full extent of
module testing to be accomplished.
To test the system controlled lamp modules:
1. Press the LIGHT button on the KeyChain
Touchpad repeatedly to turn all lights on and off.
The Control Panel responds with Lights on/off.
2. Press the Lights On button and the unit # of the
lamp module using the numeric buttons on the
Remote Handheld Touchpad to test individual
lamp modules, the Control Panel will respond
with Lights # on/off.
Siren and X-10 Lamp Module Func-
tions*
All sirens will time-out in the programmed siren time-
out (1 - 254 minutes). Siren priority is as follows: fire,
intrusion, then emergency. If an alarm of greater pri-
ority occurs during an alarm of lower priority, the
higher priority alarm sirens sound. The X-10 must be
set to unit #9 to hear emergency alarm beeps. Fire
alarms will sound a temporal 3 pattern. Temporal 3 is
0.5 seconds on, 0.5 seconds off for 3 beeps then 1.5
seconds off.
Panel Tamper
If the system is armed and the cover is opened an in-
trustion alarm will sound and the system status will
say System Access Alarm when the button is pressed.
Table 22 Alarm Siren and X-10 Light
Information
Fire
Intrusion
Emergency
X-10 Lights
Steady
Flashing
Steady
X-10 Siren
Steady
Steady
Alarm beeps
Interior & Panel
Siren
Temporal 3
Steady
Fast on/off
Exterior Siren
Temporal 3
Steady
SWS
Temporal 3
Steady
Fast on/off
* = Not Available with Basic Model